beautypg.com

User keypad and bath with airjets modes/features – Kohler Bath With Airjets K-1969 User Manual

Page 4

background image

User Keypad And Bath with Airjets Modes/Features

Power On/Off -

Turns the blower motor on and off. Symbols illuminated in blue indicate available

modes/features. Modes that are operating will display in green.

Activate Button -

Press “OK” to activate the desired mode. The active mode will flash (green).

Up Arrow -

Increases the air flow when the air flow mode is active. Increases the pulse speed when

the surge mode is active.

Down Arrow -

Decreases the air flow when the air flow mode is active. Decreases the pulse speed

when the surge mode is active.

Outer Ring -

Rotate the outer ring to the desired mode. The selected mode will flash (blue).

Indicator Bar -

Shows the air flow volume when operating in the air flow mode. Shows the surge

speed when operating in the surge mode.

Purge Mode -

Select to initiate the purge mode manually. The purge cycle will not start if there is

water in the bath. The purge mode blows any residual water out of the air channels. The blower
motor starts and runs at a low speed for about 2 minutes. An automatic purge cycle occurs when
the bath is drained and the water level falls below the level sensors.

Air Flow Mode -

In this mode, air flow is directed through any combination of airjets in the

selected zones. Air flow can be adjusted with the arrow buttons. When you select the surge mode
the air flow mode stops. When you select the air flow mode while operating in the surge mode, the
surge mode stops.

Zone 1 -

Use this mode to select or deselect the air flow through Zone 1.

Zone 2 -

Use this mode to select or deselect the air flow through Zone 2.

Zone 3 -

Use this mode to select or deselect the air flow through Zone 3.

Surge Mode -

When active, the air flow ramps up from minimum to maximum and then down

again to minimum. Adjust the surge speed between approximately 10 seconds to 60 seconds by
using the up or down buttons. Use the up and down arrow buttons to adjust the surge speed. Select
or deselect the zones when in the surge mode.

Chromatherapy Cycle (if provided) -

Chromatherapy lights will automatically and continuously

cycle through the eight colors; white, violet, indigo blue, aqua blue, green, yellow, orange and red.
One cycle through all eight colors takes approximately 1 minute.

Chromatherapy Specific-Color (if provided) -

Select this mode to choose a specific color for the

bath.

Air Flow Mode

Activates Mode Selected

Power On/Off

Indicator Bar

Decrease Flow or Surge

Increase Flow or Surge

Zone 1

Zone 2

Zone 3

Surge Mode

Purge Mode

Chromatherapy Cycle (if provided)

Chromatherapy Specific
Color (if provided)

Rotate Outer Ring to
Access Desired Mode

1159617-5-B

4

Kohler Co.