beautypg.com

Kohler Bath Whirlpool 1199250-2-A User Manual

Page 16

background image

Troubleshooting (cont.)

Symptoms

Probable Causes

Recommended Action

E.

Control does not work.

E.

Replace control.

12.

Noisy operation.

A.

Pump banding straps have not

been cut.

A.

Cut pump banding straps with tin

snips.

B.

Dry or dislodged jet O-ring

(squeal).

B.

Remove jet, replace and lubricate

O-ring, and reinstall jet.

13.

Remote control (if

equipped) does not work.

A.

Batteries improperly installed or

dead.

A.

Replace batteries.

B.

Antenna on wiring harness is

damaged.

B.

Replace wiring harness.

C.

Remote control not

programmed correctly.

C.

See remote control Homeowners

Guide or whirlpool Service

Manual.

D.

Remote control does not work.

D.

Replace remote control.

E.

Control does not work.

E.

Replace control.

Troubleshooting the Neckjet System

Symptoms

Probable Causes

Recommended Action

14.

Keypad does not respond

when neckjet mode is

selected.

A.

User keypad does not work.

A.

Replace the user keypad.

15.

Pump operates but

neckjets do not turn on.

Indicator bar on user

keypad is flashing.

A.

Pillow is not installed.

A.

Make sure pillow is properly

attached to the neckjet body.

B.

Reed switch does not work.

B.

Check reed switch wiring and

replace if necessary.

C.

Wiring harness from neckjet to

control is loose, disconnected or

damaged.

C.

Check wiring for proper

connections. Replace wiring

harness if necessary.

16.

Pump operates but

neckjets do not turn on.

Indicator bar on user

keypad is NOT flashing.

A.

Neckjet line is blocked.

A.

Disconnect neckjet hoses and

remove blockage.

B.

Wiring harness from neckjet to

control is loose, disconnected or

damaged.

B.

Check wiring for proper

connections. Replace wiring

harness if necessary.

C.

Butterfly valve does not work.

C.

Replace the butterfly valve.

D.

Control does not work.

D.

Replace control.

17.

Water flows from neckjets,

but neckjets do not pulse.

A.

Wiring harness from neckjet

pulse cannister to control is

loose, disconnected or damaged.

A.

Check wiring for proper

connections. Replace wiring

harness if necessary.

B.

Pulse cannister does not work.

B.

Replace the butterfly valve.

C.

Control does not work.

C.

Replace control.

Troubleshooting the Backjet System

Symptoms

Probable Causes

Recommended Action

18.

Backjets do not operate.

A.

Whirlpool pump is not

operating.

A.

Turn on pump.

B.

Backjet butterfly valve does not

open.

B.

Check for loose connections or

wires leading from backjet pulse

cannister to control. Replace backjet

pulse canister or control if

necessary.

1199250-2-A

16

Kohler Co.