beautypg.com

Troubleshooting – Kohler Bath Whirlpool K-1418-CT User Manual

Page 10

background image

Troubleshooting

NOTICE: This section is for general aid only. A Kohler Authorized Service Representative or qualified
electrician should correct any electrical problems. For warranty service, contact your dealer or wholesale
distributor.

Remove the Port

Insert the flange removal tool (provided) into the opening of the port.

Place your thumb against the whirlpool wall while firmly grasping the flange removal tool.

Pull the flange removal tool until the flange pulls free from the housing.

Reinstall the Port

NOTE: Do not use force when reinstalling the port.

Carefully insert the flange into the housing, then lightly push and rotate the flange until it snaps
into position.

Verify the port is installed correctly. Remove and reinstall, if necessary.

Troubleshooting Table

User Keypad and Pump
Symptoms

Probable Causes

Recommended Action

1.

User keypad does not

illuminate when power

button is pressed or outer

ring is rotated.

A.

No power to control.

A.

Check wiring and connect power.

B.

GFCI or RCD tripped.

B.

Reset GFCI or RCD.

C.

Wiring harness from user

keypad to control is loose,

disconnected or damaged.

C.

Check wiring for proper

connections. Replace wiring

harness if necessary.

D.

User keypad does not work.

D.

Replace user keypad.

E.

Control does not work.

E.

Replace control.

2.

User keypad is

illuminated, but does not

respond to buttons or

outer ring.

A.

Control program is locked.

A.

Reset GFCI or RCD.

B.

Wiring harness from user

keypad to control is loose,

disconnected or damaged.

B.

Check wiring for proper

connections. Replace wiring

harness if necessary.

C.

User keypad does not work.

C.

Replace user keypad.

D.

Control does not work.

D.

Replace control.

Flange Removal Tool

Flange

Housing

Whirlpool

1023246-5-C

10