NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

MAINTENANCE TASK

ACCOMPLISHING PERSON

PROCEDURE

Inspecting/Cleaning Burner, Logs

and Controls

Qualifi ed Service Technician

Inspect valve and ensure it is properly operating. Check piping

for leaks. Vacuum the control compartment, fi replace logs and

burner area.

Check Flame Patterns and Flame

Height

Qualifi ed Service Technician

Refer to Figure 10 on Page 11 and verify the fl ame pattern

and height displayed by the appliance conforms to the picture.

Flames must not impinge on the logs. Ensure fl ames are steady

(not lifting or fl oating).

Inspecting/Cleaning Pilot and Burner

Qualifi ed Service Technician

Refer to Figure 12 (SIT Millivolt), Figure 13 (Honeywell Millivolt)
or Figure 14 (
Electronic) on Page 12
. Remove any surface
build-up on pilot and burner assembly. Wipe the pilot nozzles,
igniter/fl ame rod and hood. Ensure the pilot fl ame engulfs the
fl ame sensor as shown.

Checking Vent System

Qualifi ed Service Technician

Inspect the vent system at the top and at the base (within the

fi rebox) for signs of blockage or obstruction. Look for any signs

of dislocation or deterioration of the vent components. Note:

Excessive condensation can cause corrosion of caps, pipe &

fi ttings (excessive condensation can be caused by long lateral

runs, too many elbows and/or exterior portions of the system

being exposed to cold weather). Also inspect wall straps or

plumbers's tape to ensure it is secure and in place.

Appliance Checkout

Qualifi ed Service Technician

Perform the appropriate appliance checkout procedure detailed

in this manual.

Replacing Rockwool Ember Materials

Homeowner/Qualifi ed Service

Technician

Remove old ember materials (rockwool) and vacuum the ember
placement area. Place new embers as described and shown in
Figures 8 & 9.

Periodically (After the Burning Season)

MAINTENANCE TASK

ACCOMPLISHING PERSON

PROCEDURE

Cleaning Firebox Interior

Homeowner

Carefully remove logs, rockwool and volcanic stone. Vacuum

out interior of the fi rebox. Clean fi rebox walls and log grate.

Replace logs, rockwool, and volcanic stone as detailed in this

manual.

Check Flame Patterns and Flame

Height

Homeowner

Refer to Figure 10 on Page 11 and verify the fl ame pattern

and height displayed by the appliance conforms to the picture.

Flames must not impinge on the logs.

Checking Vent System

Homeowner

Inspect the vent system at the top and at the base (within the

fi rebox) for signs of blockage or obstruction. Look for any signs

of dislocation of the vent components.

Cleaning Front Glass Enclosure Panel

Homeowner

Clean as necessary following the directions provided in this

manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS

WHILE HOT.

Annually (Before the onset of the Burning Season)