beautypg.com

2. system control, 2-1. specifications and functions of control port – Sony DVS-V3232B/V3232M User Manual

Page 13

background image

1-3

ROUTING SWITCHER SYSTEM (E)

1-2. System Control

*

1: The specifications of BKPF-R70. When BKPF-R70 is used, termination resistors are necessary at both ends of the cable. The cable

cannot be checked for open circuit.

*

2: Known before as switcher protocol.

1-2. System Control

1-2-1. Specifications and functions of control port

The DVS-V3232B/V6464B and HDS-V3232 digital video routing switcher is equipped with four kinds of
remote ports REMOTE 1 (S-BUS), REMOTE 2 (9-pin), REMOTE 3 (25-pin), and REMOTE 4 (monitor

S-BUS). Other switchers are equipped with three kinds of remote ports excluding REMOTE 4.

The specifications and functions of the control ports are as follows.

REMOTE 1 BNC 75

Z

Z

Z

Z

Z

47 k

Z

Z

Z

Z

Z

terminated

Protocol

S-BUS control

Data Transfer Method

BI-PHASE SPACE

Data Transfer Speed

312.5 kbps/1250 kbps

*1

Max Cable Length

500 m/125 m

*1

(BELDEN 8281 cable or equivalent)

FCS Data

HDLC CRC-CCIT

x

16

+ x

12

+ x

5

+ 1 Initial all high

Function

With this port the communication between the primary and secondary stations is performed.

Remote control units, routing switchers and display units are connected to this S-BUS data
link in order to perform system functions.

REMOTE 1 is sometimes simply called “remote” for units having this remote port only.
To distinguish the S-BUS using REMOTE 1 from the monitor S-BUS (REMOTE 4), which

will be described later, it is called standard S-BUS or simply S-BUS.

REMOTE 2 D-sub 9-pin

Protocol

RS-422A Flow control, 38.4 kbps, 100

Z /10 kZ

This port accepts three kinds of protocols.

Model

DVS-V6464B

DVS-A3232

DVS-RS1616

DVS-V1616

Protocol

DVS-V3232B

DVS-TC3232

BKPF-R70

HDS-V3232

BVS-V3232
BVS-A3232

CART PROTOCOL

Yes

Yes

No

Yes

AUDIO MIXER

Yes

Yes

Yes

No

PROTOCOL

*

2

PRODUCTION SWITCHER

Yes

No

No

No

PROTOCOL

Function

With this port communication between two units is performed. A switcher, DME, etc. are
connected to this port. The functions of the router system using this RS-422A port depend

on a superior controller so that the system may not have so many functions as S-BUS
system’s.