Read below for more detailed information – Stearns Safety & Survival 1189 User Manual
Page 5
READ BELOW FOR MORE DETAILED INFORMATION!
1. Inspecting Your PFD For Damage
Make sure that the PFD is free from rips, tears or punctures. This
type of damage on the outside covering indicates that the Inflatable
Chamber may have been exposed to potentially damaging elements.
If these defects expose the yellow inflatable chamber material,
discontinue use of the PFD until you have the PFD inspected by an
authorized repair facility. If these defects are noticed but the yellow
inflatable chamber material is not exposed, the Inflatable Chamber
should be checked for leaks. The Inflatable Chamber should also be
checked for leaks at the beginning of each season and at least every
two months during the boating season. The leak test procedure is
described under USER'S INSPECTION. (Refer to Page 10.)
2. How to Inspect the Mechanism
The mechanism is located on your right side under the protective
cover. Before inspecting the mechanism remove the CO2 cylinder to
prevent unnecessary discharge.
The CO2 cylinder contains the gas charge that will inflate your PFD
when the inflation mechanism is fired. You must verify that the CO2
cylinder installed is of the correct size specification and has not been
previously fired.
Be sure that a cylinder is inserted into the mechanism and that the
cylinder seal indicator shows Green. If the indicator shows Red, replace
with a new cylinder following the rearming instructions on back cover.
Additional Notes on CO2 Cylinders:
• FAILURE to properly rearm the inflation mechanism prior to installing
the CO2 Cylinder will result in premature activation of the cylinder.
• CO2 Cylinders are only good for one (1) inflation and cannot be
recharged.
• CO2 Cylinders are made with a protective coating that may wear off
after a period of use or exposure to the environment. When this
coating is worn off, the CO2 Cylinder may start to show some signs of
rusting. If this occurs, replace the CO2 Cylinder.
• If a gram scale (such as a postal scale) is available, it is recommended
to weigh the cylinder to verify that it meets the minimum weight
imprinted on the cylinder.
5