Material safety data sheet (1/2) – Sharp UX-340L User Manual
Page 148

146
Please check the bottom righthand corner of the product number UX-3CR on the film box, or the 
final digit of the manufacturing number on the label at the beginning of the roll of ink film. 
If an “F” appears, please read pages 146 to 147. If an “F” does not appear, please read pages 148 
to 149.
S H A R P
Revised date : .
Issued date :DEC.2.1999
MATERIAL SAFETY DATA SHEET (1/2)
MSDS No B-1021
.
Section 1. Product Identification
Product Code : UX-3CR Imaging Film
Section 2. Supplier's Name and Address
 Sharp Corporation
 22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
 Local suppliers are listed below. Please contact the nearest supplier for additional information.
Section 3. Ingredients
Ingredients
Cas No.
Proportion
OSHA PEL
ACGIH TLV
Other Limits
Carbon Black
1333-86-4
9%
3.5 mg/m
3
3.5 mg/m
3
-
Paraffin Wax (fume)
8002-74-2
23%
-
2.0 mg/m
3
-
Polyethylene terephthalate
25038-59-9
50 - 55%
-
-
-
Ethylene-vinyl acetate copolymer
24937-78-8
1 - 5%
-
-
-
Ester wax
8015-86-9
1 - 5%
-
-
-
Polyester resin
27923-68-8
1 - 5%
-
-
-
Synthetic wax
68989-34-4
1 - 5%
-
-
-
Others
-
1 - 5%
-
-
-
Section 4. Hazardous Identification (Emergency Overview)
This product is ink film for thermal transfer facsimile.
“Ink film” is a thin film coated with ink.
It is no special hazard under normal use condition.
Section 5. Health Hazard Data 
Route(s) of Entry :
Inhalation?
Skin?
Ingestion?
Not applicable
Not applicable
Possible but very unusual
Health Hazards : The ingredients are not listed in ACGIH(1986) and OSHA(1989) except carbon black and paraffin wax.
Carcinogenicity : In 1996 the IARC reevaluated carbon black as a Groupe 2B carcinogen (possible human carcinogen).
This classification is given to chemicals for which there is inadequate human evidence, but sufficient 
animal evidence on which to base an opinion of carcinogenicity. The classification is based upon the 
development of lung tumors in rats receiving chronic inhalation exposures to free carbon black at levels 
that induce particle overload of the lung. Studies performed in animal models other than rats did not 
show any association between carbon black and lung tumors.
Signs and Symptoms of Exposure : no data available
Medical Conditions Generally Aggravated by Exposure : no data available
Emergency and First Aid Procedures :
 SKIN- - - - - - - - - Wash away ink on skin
 EYE - - - - - - - - - Wash away water and consult a doctor promptly.
 INHALATION - - - Not applicable
 OTHERS- - - - - - No data available 
(Country)
(Name and Telephone Number)
U.S.A.
Sharp Document Network System of America
Telephone number for information: 1-800-237-4277
Emergency telephone number : 1-800-255-3924
Canada
Sharp Electronics of Canada Ltd.
Telephone number for information: 905-890-2100
Emergency telephone number : 1-800-424-9300
United 
Kingdom
Sharp Electronics (U.K.) Ltd.
Telephone number for information: 01923-474013
all-ux340L.book Page 146 Thursday, December 23, 1999 5:37 PM