B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS

Note: Installation and repair should be done

by a qualified service person. The appliance

should be inspected before use and at least

annually by a professional service person.

More frequent cleaning may be required due

to excessive lint from carpeting, bedding

material, etcetera. It is imperative that control

compartments, burners and circulating air

passageways of the appliance be kept clean.

Remarque : L’installation et la répara-

tion devrait être confiées à un technicien

qualifié. L’appareil devrait faire l’objet

d’une inspection par un technicien profes-

sionnel avant d’être utilisé et au moins

une fois l’an par la suite. Des nettoyages

plus fréquents peuvent être nécessaires si

les tapis, la literie, et cetera produisent

une quantité importante de pous-sière.

Il est essentiel que les compartiments

abritant les commandes, les brûleurs

et les conduits de circulation d’air de

l’appareil soient tenus propres.

do not use these appliances if any part

has been under water. Immediately call a

qualified, professional service technician

to inspect the appliance and to replace

any parts of the control system and any

gas control which have been under water.

Ne pas utiliser cet appareil s’il a été

plongé, même partiellement, dans

l’eau. Appeler un technicien qualifié

pour inspecter l’appareil et remplacer

toute partie du système de commande

et toute commande qui a été plongée

dans l’eau.

Only trim kit(s) supplied by the manufacturer

shall be used in the installation of this ap-

pliance.

Seules les trousses de garniture fournies

par le fabricant doivent être utilisées pour

l’installation de cet appareil.

These appliances comply with National Safety

Standards and are tested and listed by ITS

(Report No. 100017854) to ANSI Z21.50 (in

Canada, CSA-2.22) and to CAN/CGA-2.17-M91

in both USA and Canada (latest editions at time

of manual publication) as vented gas fireplaces.
Both millivolt and electronic versions of

these appliances are listed by ITS for instal-

lation in bedrooms in the United States (not

approved in Canada).

These appliances must not be connected to a

chimney or flue serving a separate solid fuel

burning appliance.

Installation must conform to local codes, or, in

the absence of local codes, with the National

Fuel Gas Code, ANSI Z223.1/NFPA 54 (latest

edition), or the Natural Gas and Propane Instal-

lation Code, CAN/CSA B149.1 (latest edition).

The appliance, when installed, must be electri-

cally grounded and wired in accordance with

local codes or, in the absence of local codes, with

the USA National Electrical Code, ANSI/NFPA

70 (latest edition) or, in Canada, the Canadian

Electrical Code, CSA C22.1 (latest edition).

Provide adequate clearances around air open-

ings and adequate accessibility clearance for

service and proper operation. Never obstruct

the front opening of the appliance.

These appliances are designed to operate on

natural or propane gas only. The use of other

fuels or combination of fuels will degrade

the performance of this system and may be

dangerous.

These fireplaces are designed as supplemental

heaters; therefore, it is advisable to have an

alternate primary heat source when installed

in a dwelling.

MILLIVOLT MOdELS: The millivolt appliances

are manually controlled and feature a spark

igniter (piezo) that allows the appliance's pilot

gas to be lit without the use of matches or bat-

teries. This system provides continued service

in the event of a power outage.

ELECTRONIC MOdELS: The electronic appli-

ances are manually controlled and feature an

electronic intermittent pilot ignition system.

External electrical power is required to operate

these units.

ALL MOdELS: Both millivolt and electronic

models come standard with a manually-

modulated gas valve; flame appearance and

heat output can be controlled at the gas valve.

BTU input rates for all models are listed in

Table 1, below.

Input (BTU/hr) Manually-Modulated

Gas Valves (all models)

Models

Input Rate (BTU / HR)

Nat. Gas

Prop. Gas

SLBV-35

17,000 high

13,000 low

17,000 high

14,000 low

SLBV-40

22,000 high

17,000 low

20,000 high

15,500 low

Table 1

WARNING

Improper installation, adjust-

ment, alteration, service or

maintenance can cause injury

or property damage. Refer to

this manual. For assistance or

additional information consult

a qualified installer, service

agency or the gas supplier.

WARNING

Failure to comply with these

installation instructions will

result in an improperly installed

and operating appliance, void-

ing its warranty. Any change to

this appliance and/or its operat-

ing controls is dangerous.

WARNING

Clothing or other flammable

material should not be placed

on or near the appliance.

AVERTISSEMENT

On ne devrait pas placer de

vêtements ni d’autres matières

inflammables sur l’appareil ni à

proximité.

WARNING

Any safety screen or guard

removed for servicing the appli-

ance must be replaced prior to

operating the appliance.

AVERTISSEMENT

Tout écran ou protecteur retiré

pour permettre l’entretien de

l’appareil doit être remis en

place avant de mettre l’appareil

en marche.

WARNING

Improper installation or use

of this appliance can cause

serious injury or death from

fire, burns, explosion or

carbon monoxide poisoning.

GENERAL INfORMATION

(continued)

3