Output Clipping Level

Impendance

English

8

17

8 Technical Data

Power supply unit C1-PS 60i

Mains voltage

C1-PS 60i A:

120 V AC, 50/60 Hz

C1-PS 60i J:

100 V AC, 50/60 Hz

C1-PS 60i E, C1-PS 60i UK :

220 - 240 V AC, 50/60 Hz

Power rating:

330 VA

Primary Fuses

C1-PS 60i A:

T4A

C1-PS 60i J:

T5A

C1-PS 60i E, C1-PS 60i UK :

T2A

Secondary Fuses:

2 x T8A

Bus supply voltage:

+/- 24 V DC nom.

Microphone

(balanced)

Audio inputs

Line

(balanced)

Aux

(unbalanced)

Impendance

8 kOhm

50 kOhm

Input Clipping

Level

-26 dBV

+6 dBV

+6 dBV

Phantom

Power

15 V DC

AEC / Telco

Audio Interface

(balanced)

50 kOhm

+20 dBV

8 kOhm

--

--

--

Headphone Output
Output impedance:

8 Ohm

Socket:

1/4” stereo jack socket

Connections:
Maximum number of consoles
per console-bus branch (Minicon):

15

per Sub-D 25 output:

30

Maximum total number of consoles:

60

Maximum length of a console-bus branch:

40 m

Maximum cable length from PSU to last console:

80 m

Audio outputs

Aux

(unbalanced)

Line

(balanced)

<20 Ohm

+18 dBV

+12 dBV

AEC / Telco

Audio Interface

(balanced)

200 Ohm

+18 dBV

<20 Ohm