8 technical data, Power supply unit c1-ps 60i – Shure Conference Phone User Manual
Page 18
Output Clipping Level
Impendance
English
8
17
8 Technical Data
Power supply unit C1-PS 60i
Mains voltage
C1-PS 60i A:
120 V AC, 50/60 Hz
C1-PS 60i J:
100 V AC, 50/60 Hz
C1-PS 60i E, C1-PS 60i UK :
220 - 240 V AC, 50/60 Hz
Power rating:
330 VA
Primary Fuses
C1-PS 60i A:
T4A
C1-PS 60i J:
T5A
C1-PS 60i E, C1-PS 60i UK :
T2A
Secondary Fuses:
2 x T8A
Bus supply voltage:
+/- 24 V DC nom.
Microphone
(balanced)
Audio inputs
Line
(balanced)
Aux
(unbalanced)
Impendance
8 kOhm
50 kOhm
Input Clipping
Level
-26 dBV
+6 dBV
+6 dBV
Phantom
Power
15 V DC
AEC / Telco
Audio Interface
(balanced)
50 kOhm
+20 dBV
8 kOhm
--
--
--
Headphone Output
Output impedance:
8 Ohm
Socket:
1/4” stereo jack socket
Connections:
Maximum number of consoles
per console-bus branch (Minicon):
15
per Sub-D 25 output:
30
Maximum total number of consoles:
60
Maximum length of a console-bus branch:
40 m
Maximum cable length from PSU to last console:
80 m
Audio outputs
Aux
(unbalanced)
Line
(balanced)
<20 Ohm
+18 dBV
+12 dBV
AEC / Telco
Audio Interface
(balanced)
200 Ohm
+18 dBV
<20 Ohm