Sony CDU711 User Manual

Page 27

background image

27

Environmental conditions

Operating

Temperature

5

°

C to 50

°

C (41

°

F to 122

°

F)

Humidity

10 % to 90 % (Max wet bulb 29

°

C)

Atmosphere

Non-condensing

Non-operating/Storage

Temperature

–30

°

C to 50

°

C (–22

°

F to 122

°

F)

Humidity

10 % to 90 %

Atmosphere

Non-condensing

Dimensions and mass

Dimensions

146

Ч

41.4

Ч

208 mm (w/h/d)

(5

3

/

4

Ч

1

11

/

16

Ч

8

1

/

4

inc hes)

Mass

0.90kg (2 lb)

Power requirement

Volta ge

+5 V

±

5 % DC and +12 V

±

10 % DC

Current

Tra y Open/Close
+5 V DC ;

1100 mA

+12 V DC ;

1100 mA

Seeking and Spin Up/Down
+5 V DC ;

1300 mA

+12 V DC ;

1800 mA

Hold Trac k State
+5 V DC ;

1300 mA

+12 V DC ;

750 mA

Standby/Sleep
+5 V DC ;

150mA

+12 V DC ;

20mA

Connectors

INTERFACE CONNECT OR
(with DC INPUT connector)

AMP 179376-1 or equivalent

AUDIO OUT connector

Molex 5046-04A or equivalent

Laser

Type

Semiconductor laser GaAlAs

Wave length

780 nm

Output power

0.5 mW

Design and specifications are subject to change without notice.

Specifications