beautypg.com

Installation, Operation – John Deere AC-100LP User Manual

Page 12

background image

12

Operator’s Manual

Installation

INSTALLATION

IMPORTANT: Review and understand the warnings in

the Safety Information section. They are needed to safely

operate this space heater. Follow all local ordinances and

codes when using this space heater.

WARNING: TEST ALL GAS PIPING AND

CONNECTIONS FOR LEAKS AFTER

INSTALLING OR SERVICING. NEVER

USE AN OPEN FLAME TO CHECK FOR

A LEAK. APPLY A MIXTURE OF LIQUID

SOAP AND WATER TO ALL JOINTS.

BUBBLES FORMING SHOW A LEAK.

CORRECT ALL LEAKS AT ONCE.

1. Provide propane supply system (see Propane

Supply).

2. Connect fuel gas connector fitting on hose / regulator

assembly to Propane / L.P. tank(s). Turn counterclockwise

into threads on tank valve. Tighten firmly using wrench.

IMPORTANT: Tighten regulator with vent pointing down.

Pointing vent down protects regulator from weather

damage. (Fig. 1)

3. Connect hose to inlet connector. Tighten firmly using a

wrench. (Fig. 2)

IMPORTANT: Extra hose or piping may be used if needed.

Install extra hose or piping between hose/regulator

assembly and Propane / L.P. tank. You must use the

regulator supplied with heater.

4. Open propane supply valve on Propane / L.P. tank(s)

slowly.

Note: If not opened slowly, excess-flow check valve on

Propane / L.P. tank will stop gas flow. If this happens,

close propane supply valve and open again slowly.

5. Check all connections for leaks.
6. Close propane supply valve.

Hose

Regulator

Vent (pointing

down)

Supply

Valve

Propane

Tank

Fuel Gas

Connector

(Fig. 1)

Hose

Inlet Connector

(Fig. 2)

Operation

OPERATION

WARNING: FOLLOW THE MINIMUM FRESH,

O U T S I D E A I R V E N T I L AT I O N

REQUIREMENTS. IF PROPER FRESH,

OUTSIDE AIR VENTILATION IS NOT

PROVIDED, CARBON MONOXIDE

POISONING CAN OCCUR. PROVIDE

PROPER FRESH, OUTSIDE AIR

VENTILATION BEFORE RUNNING

HEATER.

START SPACE HEATER:

1. Follow all ventilation and safety information.
2. Place the space heater in an area that provides

maximum circulation of the heated air. Follow all location

requirements noted in the Safety Information.