WArNING: FOLLOW the MINIMUM FreSh, OUtSIDe
AIr VeNtILAtION reqUIreMeNtS. IF prOper
FreSh, OUtSIDe AIr VeNtILAtION IS NOt
prOVIDeD, CArBON MONOXIDe pOISONING
CAN OCCUr. prOVIDe prOper FreSh, OUtSIDe
AIr VeNtILAtION BeFOre rUNNING heAter.
Fresh Air Opening Requirements:
Heater Size
Square Feet Opening
350,000 Btu/Hr 10.5
Note: If you use more than one heater, provide extra fresh
air. Provide a fresh air opening of at least three square feet
for each 100,000 Btu/Hr rating.
FUeLS
WArNING: USe ONLY KerOSeNe Or #1 FUeL OIL
tO AVOID rISK OF FIre Or eXpLOSION. NeVer
USe GASOLINe, NAphthA, pAINt thINNerS,
ALCOhOL Or Other hIGhLY FLAMMABLe
FUeLS.
Do not use heavy fuels such as No. fuel oil or No. diesel.
Using heavy fuels will result in:
• clogged fuel filter and nozzle
• carbon build-up on spark plug
• the need of non-toxic anti-icer in fuel during very cold
weather
IMPORTANT: Use a KEROSENE ONLY storage container.
Be sure storage container is clean. Foreign matter such as
rust, dirt or water will cause flame-out control to shut down
heater. Foreign matter may also require you to clean fuel
system often.