IDEAL INDUSTRIES 61-095 User Manual
Page 7

Page 5
Physical and Environmental Characteristics
Physical Characteristics
Description
Dimensions (H x W x D)
188mm x 66mm x 42mm
Weight (with battery)
0.3Kg
Environmental Characteristics
Description
Temperature operating
0 to + 50ºC
Non-Operating
-20 to + 60ºC
Humidity (operating)
< 80% R.H.
Altitude Operating
2,000 m (6560 ft.)
Non-Operating
12,300 m (40354 ft.)
Vibration & shock Operating
MIL-T-28800E (5 ~ 55Hz, 3g maximum)
Conductor Size
12mm (0.5”)
Indoor Use
Indoor Use
Certifications and Compliances
Safety
Designed to IEC 1010-1, UL3111-1 and CSA specifications
Input rating
IEC 1010 600V CAT. III
Over voltage category
CAT III: Distribution level mains, fixed installation.
CAT II: Local level mains, appliances, portable equipment.
CAT I: Signal level, special equipment or parts of equipment,
telecommunication, electronics.
Pollution Degree 2
Do not operate in environments where conductive pollutants may
be present.
EC Declaration of Conformity
Meets the intent of Directive 89/336/EEC for Electromagnetic
Compatibility and Low Voltage Directive 73/23/EEC for
Product Safety. Compliance was demonstrated to the following
specifications as listed in the official Journal of the European
Communities:
EN 55011 Class A: Radiated and Conducted
Emissions.
EN 50082-1 Immunity: IEC 801-2 Electrostatic Discharge
IEC 801-3 RF Radiated
EN 61010-1 Safety requirements for electrical equipment for
measurement, control, and laboratory use.
Form number TM61095