beautypg.com

Receive adjustment, 4 receive adjustment – Icom IC-F3021S User Manual

Page 19

background image

6 - 6

6-4 RECEIVE ADJUSTMENT

Select an adjustment item using [

↑] / [↓] keys, then set to the specifi ed value using [←] / [→] keys on the connected PC’s keyboard.

ADJUSTMENT

ADJUSTMENT CONDITION

MEASUREMENT

VALUE

UNIT

LOCATION

RECEIVE
SENSITIVITY
[BPF (T1)]
[BPF (T2)]

NOTE:

“RECEIVE SENSITIVITY” must be adjusted before “S-METER.” Otherwise, “S-METER” will not be

adjusted properly.

1

• Channel

: CH 2

[MIC/SP]

jack

Connect the SINAD meter
with an 8

Ω load to the JIG

cable.

Minimum distortion

level

• Connect the SSG to the antenna connec-

tor and set as;

Frequency
Level
Modulation
Deviation
• Receiving

: 136.000 MHz
: +20 dBµ

(–87 dBm)

: 1 kHz
: ±3.5 kHz

CONVENIENT:

The “RECEIVE SENSITIVITY” can be adjusted automatically.
1: Put the cursor on “BPF ALL” and push [ENTER] key.
2: The connected PC tunes BPF’s to peak levels automaticaly.

S-METER
[RSSI]

1

• Channel

: CH 2

Push the [ENTER] key on the connected PC’s keyboard to set
“S3” level.

• Connect the SSG to the antenna connec-

tor and set as;

Frequency
Level
Modulation
Deviation
• Receiving

: 136.000 MHz
: +23 dBµ

(–84 dBm)

: 1 kHz
:

±3.5 kHz

2

• Set the SSG as;
Level
• Receiving

: –7 dBµ

(–114 dBm)

Push the [ENTER] key on the connected PC’s keyboard to set
“S1” level.

SQUELCH
[SQL]

1 • Channel

: CH 9

External

speaker

Connect an 8

Ω speaker to

the JIG cable.

Set the [SQL] to the
value that the audio
signals just appears.

• Close the squelch by adjusting the value of
[SQL] item on the CS-F3020 ADJ’s screen.
• Connect the SSG to the antenna connec-

tor and set as;

Frequency
Level
Modulation
Deviation
• Receiving

: 155.000 MHz
: –15 dBµ

(–122 dBm)

: 1 kHz
:

±3.5 kHz

†;

The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.

This manual is related to the following products: