InFocus CR 18DMR User Manual
Page 17
16
BATTERY REMOVAL/INSTALLATION
CAUTION
Be sure to keep the switch turned off and the lock-
off button moved to right position (lock position)
(See Fig. 17).
1. Battery removal
Hold the housing tightly and push the battery latches
to remove the battery (see Figs. 1 and 2).
CAUTION
Never short-circuit the battery.
2. Battery installation
Insert the battery while observing its polarities (see
Fig. 2).
CHARGING
〈UC24YFA〉
Before using the Cordless Reciprocating Saw, charge
the battery as follows.
1. Connect the charger’s power cord to a receptacle
When the power cord is connected, the charger’s
pilot lamp will blink in red (At 1-second intervals).
2. Insert the battery into the charger
Firmly insert the battery into the charger till it
contacts the bottom of the charger and checking
the polarities as shown in Fig. 3.
3. Charging
When inserting a battery in the charger, charging
will commence and the pilot lamp will light up
continuously in red.
When the battery becomes fully recharged, the pilot
lamp will blink in red (At 1-second intervals) (See
Table 1).
(1) Pilot lamp indication
The indications of the pilot lamp are shown in
Table 1, according to the condition of the charger
or the rechargeable battery.
Table 1
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Lights continuously
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for 0.1
seconds. (off for 0.1 seconds)
Lights continuously
Before
charging
While
charging
Charging
complete
Charging
impossible
Charging
impossible
Blinks
(RED)
Lights
(RED)
Blinks
(RED)
Flickers
(RED)
Lights
(GREEN)
Malfunction in the battery
or the charger.
The battery temperature
is high, making recharg-
ing impossible.
(2) Regarding the temperatures of the rechargeable
battery.
The temperatures for rechargeable batteries are as
shown in the table 2, and batteries that have become
hot should be cooled for a while before being recharged.
Table 2
(3) Regarding recharging time
Depending on the type of battery, the recharging
time will become as shown in Table 3.
Table 3
Recharging time (At 20°C)
NOTE
The recharging time may vary according to
temperature and power source voltage.
4. Disconnect the charger’s power cord from the
receptacle
5. Hold the charger firmly and pull out the battery
NOTE
After operation, pull out batteries from the charger
first, and then keep the batteries properly.
Temperatures at
Battery type
which the battery
can be recharged
EB1820L
–5°C – 60°C
EB1826HL, EB1830HL
0°C – 45°C
Battery type
Recharging time
EB1820L
Approx. 50 min.
EB1826HL
Approx. 60 min.
EB1830HL
Approx. 70 min.