Environmental requirements, 1 temperature, 2 thermal shock (shipping) – Intel ATX 0.9 User Manual
Page 26: 3 humidity, 4 altitude, 5 mechanical shock
Intel ATX Power Supply Design Guide
Version 0.9
Page 26
5. Environmental Requirements
5.1 Temperature
Operating ambient
+10 °C min
+50 °C max
(At full load, with a maximum rate of change of 5 °C/10
minutes, but no more than 10 °C/hr.)
Nonoperating ambient
-40 °C to +70 °C
(Maximum rate of change of 20 °C/hr.)
5.2 Thermal Shock (Shipping)
Nonoperating
-40 °C to +70 °C; 15 °C/min
≤
dT/dt
≤
30 °C/min; 50 cycles;
Duration of exposure to temperature extremes for each half
cycle shall be 30 minutes.
5.3 Humidity
Operating
To 85% relative humidity (noncondensing)
Nonoperating
To 95% relative humidity (noncondensing)
Note: 95% RH is achieved with a dry bulb temperature of
55 °C and a wet bulb temperature of 54 °C.
5.4 Altitude
Operating
To 10,000 ft
Nonoperating
To 50,000 ft
5.5 Mechanical Shock
Nonoperating
50 g, trapezoidal input; velocity change
≥
170 in/s.
Three drops on each of six faces are applied to each sample.