11

6

ABOUT CE

• Typical installation example
A UHF base station transmitter is to be installed on
the roof of an office.

The transmit power is 25 watts, there is 20 m of
RG-213 coaxial cable and the antenna is vertically
polarised dipole.

The specification of the RG-213 cable gives a loss
of 1.5 dB/10 m. There will be 3 dB loss for the 20 m
length used.

The RF power at the antenna input will be 12.5 watts.

The dipole antenna has a forward gain of 0 dBd or
1.6, giving an EIRP of 20 watts.

Referring to the table above for VHF/UHF vertical
antennas, this gives a front clearance distance of ap-
prox. 1.5 m and a height clearance of 3 m.

The antenna installation needs to ensure that the low-
est part of the antenna is at least 3 m above any point
where the general public may gain access and that
they cannot pass within 1.5 m in front of the antenna.

If there is no general public access to the roof in
question then the antenna could be mounted on a
short stub mast. If there is such access to the roof
then the antenna could be mounted on top of a short
mast of 3.2 m high. The mast position should be such
that the antenna can radiate clearly i.e. no other ob-
ject or structure is within 1.5 m (preferably more).

It should be relatively easy to fulfil all these recom-
mendations.

If for any reason such minimum distances are impos-
sible to guarantee then some type of access con-
trol fence or barrier around the antenna installation
should be provided.

Should a Yagi type antenna be used then you will
have to obtain a 3 dimensional polar plot of the radia-
tion characteristic from the manufacturer and evaluate
the clearance distances in both vertical and horizontal
planes.

• Operating Notes
All of the above comments on RF safety assume that
the radio is transmitting continuously in a constant
carrier mode such as FM or RTTY etc.

The RF exposure limits recommended by the EC are
based on the mean power averaged over a 6 minute
period.

Therefore if the total transmit time during any 6
minute period is reduced, then the installation will be
even further within the recommended limits.

CE Versions of the IC-FR6100 which dis-
play the “CE” symbol on the serial number
seal, comply with the essential require-
ments of the European Radio and Tele-
c o m m u n i c a t i o n Te r m i n a l D i r e c t i ve
1999/5/EC.

This warning symbol indicates that this
equipment operates in non-harmonised
frequency bands and/or may be subject to
licensing conditions in the country of use.
Be sure to check that you have the correct
version of this radio or the correct pro-
gramming of this radio, to comply with na-
tional licensing requirement.

• List of Country codes (ISO 3166-1)

1 Austria

AT

2 Belgium

BE

3 Bulgaria

BG

4 Croatia

HR

5 Czech Republic

CZ

6 Cyprus

CY

7 Denmark

DK

8 Estonia

EE

9 Finland

FI

10 France

FR

11 Germany

DE

12 Greece

GR

13 Hungary

HU

14 Iceland

IS

15 Ireland

IE

16 Italy

IT

17 Latvia

LV

18 Liechtenstein

LI

19 Lithuania

LT

20 Luxembourg

LU

21 Malta

MT

22 Netherlands

NL

23 Norway

NO

24 Poland

PL

25 Portugal

PT

26 Romania

RO

27 Slovakia

SK

28 Slovenia

SI

29 Spain

ES

30 Sweden

SE

31 Switzerland

CH

32 Turkey

TR

33 United Kingdom

GB

Country

Codes

Country

Codes

This manual is related to the following products: