Appendix c – specification – I.R.I.S. Touch 200 User Manual
Page 19

Iris Touch 200 Range Dialer Installation Manual
14
Appendix C – Specification
Alarm Dialer Interface
Two wire interface via RJ11 socket
40V feed at 12mA
Ringing voltage 40V P-P to REN4 for incoming calls
Off hook detection with dial-tone presented to alarm dialer
DTMF tone recognition for dialing outgoing calls and alarm signaling
Ethernet Interface
10Mbps and 100Mbps (10/100BaseT) with auto-negotiation
UTP with standard RJ45 socket for CAT-5 cabling
Dynamic IP addressing (DHCP) or fixed
GSM/GPRS Interface
Dual band GSM 900 MHz and DCS 1800 MHz
MMCX socket for antenna connection
IP
TCP ports (outbound): 51292 (diagnostics), 52737 (polling), 53165 (alarms)
UDP ports for upload/download 8738 and 8739
PIN Inputs
Maximum input voltage range
0V to +24V
Input ‘low’ threshold
< 2V
Input ‘high’ threshold
> 3V
Input pull-up impedance
Internal 10K to 5V supply
Relay Outputs
Maximum operating voltage
24V
Maximum current rating
1A
Power Supply
Supply voltage
9 - 30V DC
Ethernet only (typical current) dialer on hook
145mA (supply at 12v)
Ethernet only (typical current) dialer off hook
175mA (supply ay 12V)
With GSM/GPRS (typical current) dialer on hook
185mA (supply at 12V)
With GSM/GPRS (typical current) dialer off hook
215mA (supply at 12V)
Note: These figures are based upon the Ethernet link being connected. With GSM/GPRS there will
also be additional transient peak current of up to 250mA required as GSM and GPRS transmissions
(e.g. for network registration and calls) are made.
Weights
Dialer unit
300g
Fully packaged
500g