InFocus DV 14DL User Manual
Page 16
English
16
⅜ Regarding the temperature of the rechargeable battery
The temperatures for rechargeable batteries are as shown in the table below, and
batteries that have become hot should be cooled for a while before being recharged.
Table 3
Recharging of batteries that have become hot
4. Disconnect battery charger from the receptacle
CAUTION:
Do not pull the plug out of the receptacle by pulling on the cord.
Make sure to grasp the plug when removing from receptacle to avoid damaging cord.
5. Remove the battery from the battery charger
Supporting the battery charger with hand, pull out the battery from the battery charger.
CAUTION:
●
Repair is required if the receptacle is not secured properly or the power cord does not
stay in the receptacle. Consult your electrician. Using the charger in this condition
may lead to fire.
●
If the charge status lamp is blinking orange rapidly (in 0.2 second intervals) and the
buzzer sounds intermittently for 5 seconds, check that the hole for connecting the
battery is not obstructed. Remove any obstructions. If no obstructions are found, the
battery or charger may be malfunctioned. Return both to your place of purchase.
●
If the charge time lamp does not light when the power cord is connected to the
receptacle, disconnect the power cord, and check that the battery is attached correctly.
●
The battery retains heat when used or left for prolonged periods in direct sunlight. In
this state, the charge time lamp flashes red, and the battery cannot be charged
immediately. Leave the battery inserted in the charger, and charging will commence
when the battery cools down.
●
If the lamp goes out while charging, disconnect the power cord, and leave for 3 to 5
minutes before reconnecting. If the problem persists, call for repairs.
●
Leave 5 minutes between charging batteries as the charger may overheat leading to
malfunction.
●
The battery life is finished if it can only be used for short periods even when fully
charged. Purchase a new battery. Continuing to use a depleted battery may cause the
charger to malfunction.
NOTE:
⅜ Charging times may be longer depending on the surrounding temperature and battery
conditions.
⅜ Charge time lamp indications are only a guide, and may vary depending on the
surrounding temperature and battery conditions.
⅜ Remove the battery from the charger when not in use.
Rechargeable batteries
Temperatures at which the battery can be recharged
BCL1430, EBL1430, EBM1430 32°F—122°F (0°C—50°C)