3 nvr comms, 4 diagnostic mode, String “ set-up mode”,odh,n1,n2,n3,n4 – Intelligent Motion Systems intell-print om-192-s User Manual
Page 12

12
If the printer is turned on while pressing the SEL and FEED buttons,
simultaneously, and only the SEL button is released, the printer will print : “nvr
comms ready>”
At this point the printer is waiting to receive data in the following format : SET-
UP mode + Carriage Return +n1+…n10
(n1 to n10 are hex number) the SET-UP mode followed by a carriage return
indicates that the printer should expect parameter data as shown in the table
below.
Upon receiving information in the correct format, the printer will print : “data
ok,nvr updated !”.
Note : If no data is received within 15 seconds or the FFED button is released
before the procedure is complete, then the new setting will not be saved and the
printer will print : “set error nvr unchanged “.
8.3 NVR COMMS
STRING “ SET-UP MODE”,ODH,N1,N2,N3,N4…..
0
1
2
3
4
5
6
7
8
9
10
1
Data bit
7
8
2
Parity
EVEN
ODD
NONE
3
Baud rate
19200
9600
4800
2400
4
Country
Denmark2
Norway
Japan
Spain
Italy
Swede
n
Denmark
I
U.K.
German
y
Franc
e
U.S.A.
5
Print mode
DATA
TEXT
6
Auto off
Disable
1MIN
5MIN
7
Emulation
ESC/PO
S
560
Standar
d
8
Printing
Invert
Norma
l
9
Zero Status
10
Reverse
future
8.4 Diagnostic Mode
To get in the diagnostic mode, perform self-test and keep pressing the FEED
button until “diagnostic modes” is printed. Press the FEED button to end. The
power-on indicator will flash every two seconds. Following is an example of the
diagnostic mode:
Abc de fg
…….normal print
Abcide nfogm ……diagnostic print out
In the above example the following sequence of characters was sent :
Character f, single width(o),character g, carriage return(m).