04. VOLUME Gain Data

Function
The external control equipment changes the VOLUME gain data of the plasma
monitor.

Transmission Data

DFH

80H

60H

7FH

03H

DATA00 DATA01 DATA02 CKS

DATA00: USER SOUND Gain Flag

05H

DATA01: VOLUME Gain Flag

01H

DATA02: VOLUME Gain

00H: Step 0

0AH: Step 10 (Default)

2AH: Step 42

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER SOUND Gain Flag

05H

DATA01: VOLUME Gain Flag

01H

05. AUDIO Mute On

Function
The external control equipment switches on AUDIO Mute of the plasma monitor.

Transmission Data

9FH

80H

60H

3EH

00H

CKS

ACK

3FH

60H

80H

3EH

00H

CKS

06. AUDIO Mute Off

Function
The external control equipment switches off AUDIO Mute of the plasma monitor.

Transmission Data

9FH

80H

60H

3FH

00H

CKS

ACK

3FH

60H

80H

3FH

00H

CKS

07. CONTRAST Gain Data

Function
The external control equipment changes the CONTRAST gain data of the plasma
monitor.

Transmission Data

DFH

80H

60H

7FH

03H

DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: CONTRAST Gain Flag

07H

DATA02: CONTRAST Gain

CCH : -52

FFH: -01
00H: 0
01H: +01

14H: +20

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: CONTRAST Gain Flag

07H

08. BRIGHT Gain Data

Function
The external control equipment changes the BRIGHT gain data of the plasma
monitor.

Transmission Data

DFH

80H

60H

7FH

03H

DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: BRIGHT Gain Flag

08H

DATA02: BRIGHT Gain

E0H: -32

FFH: -01
00H: 0
01H: +01

20H: +32

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: BRIGHT Gain Flag

08H

09. SHARPNESS Gain Data

Function
The external control equipment changes the SHARPNESS gain data of the
plasma monitor.

Transmission Data

DFH

80H

60H

7FH

03H

DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: SHARPNESS Gain Flag

06H

DATA02: SHARPNESS Gain

F0H: -16

FFH: -01
00H: 0
01H: +01

10H:+16

Only when a RGB signal is connected
DATA02: SHARPNESS Gain

01H: 1
02H: 2
03H: 3
04H: 4

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: SHARPNESS Gain Flag

06H