Serial settings – Moxa Technologies NE-4100 User Manual
Page 43
NE-4100 Series User’s Manual
Web Console Configuration
6-8
Serial Settings
Click on the Serial Settings link on the left side of the screen to display serial settings. Make
necessary changes to the settings and click on submit to validate the modifications.
Port alias
Setting
Factory Default
Necessity
1 to 15 characters
(E.g., PLC-No.1)
None Optional
Port Alias is specially designed to allow easy identification of the serial devices which are
connected to NE-4100 Series’ serial port.
Serial Parameters
Check the serial communication parameters in your Serial Device’s user’s manual. You should set up
NE-4100’s serial parameters with the same communication parameters used by your serial devices.
Baud rate
Setting
Factory Default
Necessity
50 bps to 115.2 Kbps
115.2 Kbps
Required
NE-4100 supports a baud rate setting from 50 bps to 115.2 Kbps.
Data bits
Setting
Factory Default
Necessity
5, 6, 7, 8
8
Required
When the user sets Data bits to 5 bits, the stop bits setting will automatically change to 1.5 bits.
Stop bits
Setting
Factory Default
Necessity
1, 2
1
Required
Stop bits will be set to 1.5 when Data bits is set to 5 bits.
Parity
Setting
Factory Default
Necessity
None, Even, Odd, Space, Mark
None
Required