MicroNet Technology SP616DB User Manual
Page 3
3
POWER
This LED comes on when the switch is properly connected to power and turned on.
TX/FX Push Button
The push button is located at the right side of port 16 (SP616DB) or port 24 (SP624DB).
Release this button to use RJ-45 port 16 (SP616DB) or port 24 (SP624DB), and press this button
to use the 100BASE-FX module.
IP RESET Push Button
Press the front panel IP RESET push button for around five seconds to reset the Switch back to
default IP Address (192.168.1.10).
Port Status
The RJ-45 ports are numbered from 1 to 16 (SP616DB), or from 1 to 24 (SP624DB).
LEDs
Label
Status
Indication
On
Power is feeding in.
Power is switched off.
POWER
Off
Improper connection.
On
A valid network connection. LNK stands for LINK.
LNK
Off No
connection.
Flashing Transmitting or receiving data. ACT stands for
ACTIVITY.
CONSOLE
ACT
Off
Neither connection nor activity.
On
A valid network connection. LNK stands for LINK.
Flashing Transmitting or receiving data. ACT stands for
ACTIVITY.
LNK/ACT
Off
Neither connection nor activity.
On
A valid 100Mbps connection.
PORT
SPEED
Off
A valid 10Mbps connection.
On
A valid network connection. LNK stands for LINK.
LNK
Off No
connection.
Flashing Transmitting or receiving data. ACT stands for
ACTIVITY.
FX
ACT
Off
Neither transmitting nor receiving data.
Table 1: SP616DB/SP624DB LED Indication