beautypg.com

Electrical connection – Moffat MSF 611 User Manual

Page 16

background image

16

Electrical Connection

The oven is designed to be connected to 230 V
(50 Hz) electricity supply.
The oven has an easily accessible terminal
block which is marked as follows:
Letter L

-

Live terminal

Letter N

-

Neutral terminal

or E

-

Earth terminal

THIS OVEN MUST BE EARTHED

The cable used to connect the oven to the
electrical supply must comply to the
specifications given below.

It is necessary that you install a double pole
switch between the oven and the electricity
supply (mains), with a minimum gap of 3mm
between the switch contacts and of a type
suitable for the required load in compliance
with the current rules.
The switch must not break the yellow and
green earth cable at any point.
the yellow and green earth cable should be
2-3 cm longer than the other cables.
Important
After installation and connecting, the cable
must be placed so that it cannot at any point
reach a temperature of more than 60°C above
the ambient temperature.
Before the oven is connected, check that the
main fuse and the domestic installation can
support the load and that the power supply is
properly earthed.

The manufacturer declines any
responsibility should these safety
measures not be carried out.

Connection

Min. size

Cable / flex Fuse

via

Cable/flex type

13 A socket

2.5 mm

2

3 core

13 A

outlet

butyl

min.

13 A spur box

insulated

Cooker

2.5 mm

2

PVC/PVC

13 A

Control

twin and

Circuit

earth