beautypg.com

Important, Installation instructions, Step 13 connect water supply – GE PDW8100 User Manual

Page 10: Step 14 connect drain line, Drain line installation

background image

Installation Instructions

10

STEP 13 CONNECT WATER SUPPLY

Connect water supply line to 90

°

elbow.

• Slide compression nut, then ferrule over end of

water line.

• Insert water line into 90

°

elbow.

• Slide ferrule against elbow and secure with compres-

sion nut.

IMPORTANT

Check to be sure

that door spring does not rub or contact the fill hose or
water supply line. Test by opening and closing the door.
Re-route the lines if a rubbing noise or interference
occurs.

Figure CC

• If a longer drain hose is required, add up to 42" of

length for a total of 10 ft. to the factory installed hose.
Use 5/8" or 7/8" inside diameter hose and a coupler to
connect the two hose ends. Secure the connection
with hose clamps.

Figure DD

STEP 14 CONNECT DRAIN LINE

FOLLOW ALL LOCAL CODES AND ORDINANCES.

The drain hose molded end will fit 5/8", 3/4" or 1"
diameter connections on the air gap, waste tee or
disposer. Cut on the marked line as required for your
installation.

DRAIN LINE INSTALLATION

• Connect drain line to air gap, waste tee or disposer

using either previously determined method.

Waste Tee Installation

Method 1 – Air gap with waste tee or disposer

Disposer Installation

Waste Tee Installation

Method 2 – Built-in “High drain loop” with waste tee or
disposer

Disposer Installation

Figure FF

Figure GG

• Secure the drain hose to the air gap, waste tee or

disposer with clamps.

NOTE: TOTAL DRAIN HOSE LENGTH MUST NOT EXCEED
10 FEET FOR PROPER DRAIN OPERATION.

IMPORTANT

When connecting drain line to
disposer, check to be sure that drain
plug has been removed. DISH-
WASHER WILL NOT DRAIN IF PLUG IS LEFT IN PLACE.

TIP: Avoid unnecessary service call charges. Always be
sure disposer drain plug has been removed before
attaching dishwasher drain hose to the disposer.

Figure EE

Cutting Lines

1"

3/4"

5/8"

IMPORTANT: Do not cut corrugated

portion of hose

18"

Min.

18"

Min.

90

°

Elbow

Ferrule

90

°

Elbow

Hot Water

Supply Line

Compression Nut

Door Spring

Remove

Hopper

Plug

Hose Clamp

Coupler

Hose Clamp

This manual is related to the following products: