DIAGNOSTIC STATUS CODES

TRANSISTOR PUMP CONTROL

Page 50

January 2000

PUMP

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-146

“Look Ahead” test for T2 volts
less than 12% of battery volts.

This status code will be displayed when the voltage at T2 is
less than 12% of battery volts.

MEMORY RECALL

YES

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Pump

Controller


SYMPTOM
Pump control will not operate.

POSSIBLE CAUSE
Check for short circuit from the
motor armature to the frame of
the vehicle.

Control is defective.

=Replace controller unit.

POWER

CONNECTIONS

POS

A1

NEG

A2

FI

EL

D

ARMATURE

+

-

FU1

FU3

KEY SWITCH

P1

P2

P3

P12

LINE

FU6

P19

P21

TO

TRACTION

CARD

SPEED L

IMI

T 1

SPEED L

IMI

T 2

SPEED L

IMI

T 3

TO TRACTION

P10 - BDI

PY7

PY12
PY10
PY11

PUMP

STATUS

CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-150

Capacitor volts are low after the line
contactor closes.

This status code will be displayed when the capacitor voltage
is less than 85%of the battery voltage in the run mode.

MEMORY

RECALL

YES

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits

valid for

Pump

Controller


SYMPTOM
Pump control will not operate.

POSSIBLE CAUSE
Defective line contactor.

=

Check for open line contactor power
tips.


Check for loose or open connections in
cables from battery positive to control
positive circuit.

Defective power fuse.

=

Check power fuse for open circuit.


No battery voltage at P1.

=

Check for battery voltage at POS and
P1.

=

Check for loose connection at P1.

POWER

CONNECTIONS

POS

A1

NEG

A2

FI

EL

D

ARMATURE

+

-

FU1

FU3

KEY SWITCH

P1

P2

P3

P12

LINE

FU6

P19

P21

TO

TRACTION

CARD

SPEED L

IMI

T 1

SPEED L

IMI

T 2

SPEED L

IMI

T 3

TO TRACTION

P10 - BDI

PY7

PY12
PY10
PY11