Product design – Goodman Mfg UPFLOW/HORIZONTAL GME8 User Manual
Page 7
![background image](/manuals/112500/7/background.png)
7
PRODUCT DESIGN
*
All installas above 7,000 ft. require a pressure switch change.
For installations in Canada, the GME8 furnace is certified only to 4,500 ft.
*
Negative pressure readings are in inches of water column (*w.c.)
Part Number
20162903
Open Setting (°F)
160
GME80703BXC*
1
GME80905CXC*
1
GME81155CXC*
1
PRIMARY LIMIT
Part Number
B1370145
Open Setting (°F)
300
GME80703BXC*
1
GME80905CXC*
1
GME81155CXC*
1
ROLLOUT LIMIT SWITCHES
MODEL
TRIP POINT
ID BLOWER
PRESSURE
SWITCH
ID BLOWER
PRESSURE
SWITCH
PART #
GME80703BXC*
-0.70
B1370158
GME80905CXC*
-0.75
B1370179
GME81155CXC*
-1.40
B1370156
PRESSURE SWITCH TRIP POINTS
AND USAGE CHART
Part Number
0130F00038
Open Setting (°F)
120
GME80703BXC*
1
GME80905CXC*
1
GME81155CXC*
1
AUXILIARY LIMIT SWITCHES