beautypg.com

Installation, Commissioning – Stovax 7129 User Manual

Page 9

background image

9

INSTALLATION

3. COMMISSIONING

3.1 Check there are no leaks in the water system and all internal parts are correctly fitted,

all seals are undamaged and the air controls and door catch are operating freely. The fit

of the door may be adjusted if required by moving the hinge blocks. This may be done

by loosening the hinge clamping nuts, and re-tightening when the correct fit is

achieved.

3.2

Carry out a final smoke draw test on the installed stove, by first warming the flue with a

blow-lamp, or similar, for about 10 minutes. Then place a smoke pellet in the stove,

with the air controls open, and close the door. Smoke should now be drawn up the flue

and be seen to discharge at the terminal. This test should be completed with all doors

and windows in the room where the stove is fitted closed. Should this test fail the

suitability of the flue system should be re-checked.

3.3

Light the stove and gently allow the temperature to increase slowly to operating levels.

Check that no combustion products are entering the room. When the stove has

reached a steady operating condition open the main firedoor and carry out a spillage

test with a smoke match or pellet around the door opening. If excessive spillage does

occur allow the stove to cool and re-check the suitability of the flue system.

3.4

Check heating system for correct operation and any leaks.

3.5

Explain the safe operation of the stove and the use of the controls to the user, along

with the need to only use suitable fuels. Also explain the cleaning and routine

maintenance requirements.

3.6

Explain the requirements to use a suitable fireguard when children, elderly or infirm

persons may be near the stove.

3.7

Record dealer/supplier details and installer details on page 2.

3.8

Record serial number on page 2.

3.9

Give this booklet to the customer.