beautypg.com

Installation preparation, Prudence, Drain requirements – GE ZBD6905 User Manual

Page 6: Determine drain method, Cabinet preparation

background image

DRAIN REQUIREMENTS

• Follow local codes and ordinances.
• Do not exceed 10 feet distance to drain.
• To prevent back flow into the dishwasher, connect

drain line to an air gap or use a 30” high drain loop,
depending on local codes.

• Air gap must be used when waste tee or disposer

connection is less than 18” above the floor to prevent
siphoning.

DETERMINE DRAIN METHOD

The type of drain installation depends on the following
questions.

Do local codes or ordinances require an air gap?

Will waste tee or disposer connection be less than 18”
above the floor?

Will installation have a high drain loop less than 30”
above the floor?

If the answer to ANY of these questions is YES, Method 1
MUST be used.
• If all answers are NO, either method may be used.

Method 1 – Air Gap with Waste Tee or Disposer
An air gap must be used when the waste tee or disposer
connection is less than 18” from the floor.

Method 2 – High Drain Loop with Waste Tee or
Disposer
Install waste tee or disposer and air gap according
to manufacturer’s instructions.

CABINET PREPARATION

• Drill a 1-1/2” dia. hole in the cabinet wall within

the shaded areas shown for the drain hose connec-
tion. The hole should be smooth with no sharp
edges.

12"

Min.

30"

Min.

18"

Min.

30"

Min.

An air gap MUST BE USED if the drain hose is con-
nected to a waste tee or disposer lower than 18” above
the floor level.
• Failure to provide the proper drain connection using

an air gap or a 30” min. high drain loop will result in
improper draining of the dishwasher which may cause
damage or poor wash performance.

Installation Preparation

6

Il DOIT Y AVOIR une coupure antirefoulement si le
tuyau de vidange est branché sur un raccord d’égout ou
un broyeur d’ordures à moins de 46␣ cm (18 po) du sol.
• Si la vidange n’est pas branchée correctement en

utilisant une coupure antirefoulement ou un boucle
d’égout d’au moins 76 cm (30 po) de haut,
l’écoulement de l’eau du lave-vaisselle n’est pas bon,
ce qui peut causer des dommages ou un mauvais
lavage de la vaisselle.

PRUDENCE

This manual is related to the following products: