Wiring diagrams, Gch9*****xac – Goodman Mfg 40'' 95% Gas Furnace GCH9 User Manual

Page 16

background image

16

WIRING DIAGRAMS

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

GCH9*****XAC

HIGH VOL

T

A

G

E

!

DIS

C

ONNECT

AL

L

POW

E

R BEF

O

RE

SERVICI

NG OR IN

S

T

A

L

L

IN

G

T

H

IS

UNIT

.

M

U

L

T

IPL

E

PO

W

E

R SO

UR

CES M

A

Y BE P

R

ESEN

T

.

F

A

IL

URE

T

O

DO

SO

M

A

Y CAUS

E PRO

P

ERTY DAM

A

G

E

,

PERSO

NAL

I

N

J

U

R

Y

O

R

DE

A

T

H

.

R

YL YELLOW
OR ORANGE

PU PURPLE
GN GREEN
BK BLACK

BR BROWN
WH WHITE

BL BLUE

GY GRAY
RD RED

COLOR CODES:

LOW VOLTAGE (24V)

LOW VOLTAGE FIELD

HI VOLTAGE (115V)

HI VOLTAGE FIELD

NOTES:

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

0140F00647 REV. B

OR (MED LOW)

BL (MED)

RD (LOW)

GAS VALVE

C

PM

C

G

W

INTERNAL TO

INTEGRATED CONTROL

JUNCTION

EQUIPMENT GND

FIELD GND

DIAGNOSTIC
LED

2 CIRCUIT
CONNECTOR

HOT
SURFACE
IGNITER

OVERCURRENT

PROT. DEVICE

IGNITER

TH (3)

INTEGRATED
CONTROL MODULE

JUNCTION BOX

LINE-H

XFMR-H

IN
TEG

R

A

T

ED
C

O

NT
ROL

MOD

U

LE

IN
TE
GR

A

T

ED

CO

NTR

O

L

MODU

L

E

GND

DISCONNECT

L

N

DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE
PROPERLY
POLARIZED
AND GROUNDED.

OVERCURRENT PROTECTION DEVICE

OR

GY

RD

BL

BK

4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME, DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS. UNUSED

BLOWER LEADS MUST BE PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED.

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL

HAVING A TEMPERATURE RATING OF AT LEAST 105

TERMINAL

SWITCH (PRESS.)

5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

PK PINK

115 VAC HOT AND PARK TERMINALS

LINE-H

FLAME
SENSOR

FRONT COVER
PRESSURE SWITCH

( SINGLE CONTROL ON 45K BTU )

N
O

C

GY

BK

PLUG CONNECTION

FIELD SPLICE

SWITCH (TEMP.)

OR

24V THERMOSTAT

CONNECTIONS

GR

GND

115 VAC

24 VAC

BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)

DOOR
SWITCH

WARNING:DISCONNECT POWER BEFORE
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.

BK

GND

DISCONNECT

L

N

WH

JUNCTION
BOX

1

OR

ID BLOWER
PRESSURE
SWITCH

HEAT-H

GND

WH

RD

WH

GND

BURNER COMPARTMENT

BLOWER COMPARTMENT

NOTE 4

SEE

N
O

COOL-H

BK (HI)

BR

BR

CAPACITOR

YL

WH

YL

CONTROL

PRIMARY LIMIT

AUTO RESET

BL

PU

MANUAL RESET ROLLOUT LIMIT CONTROL(S)

RD

OR

PK

BK

WH

WH

BLOWER

INDUCED DRAFT

C

CIRCULATOR

BLOWER

FS

HI

HE

AT

-H

LO

HE

AT-

H

IGNITER

HOT SURFACE

IND

IGN

EAC-H

AIR CLEANER

ELECTRONIC

BLWR

CIRCULATOR

BLWR

ID

FLAME SENSOR

115 VAC

TRANSFORMER

40 VA

24 VAC

GND

LIMIT CONTROL

AUTO RESET PRIMARY

(SINGLE CONTROL ON 45K BTU)

LIMIT CONTROL(S)

MANUAL RESET ROLLOUT

RO1 (5)

RO2 (11)

HLO (1)

HLI (7)

MVC (9)

GND (8)

TR (6)

OR

WH

WH

BL

YL

OR

RD

GR

BR

PK

PU

GY

WH

115

VA
C

NE
UT
RA
L

BK

BK

GY

24
V

T

HER

MOST

A

T

CON

N

E

C

TI

ONS

MICRO

TO

C

G

Y

W

R

TRANSFORMER

40 VA

2

WH

OR

BL

YL

OR

OR

GY

PU

RD

OR

GY

WH

XF
M

R

-H

TE
R

M

IN

A

L

S

GY

OR

GR

BR

1

2

3

12

11

10

9

8

7

6

5

4

WARNING:

°C. USE COPPER CONDUCTORS ONLY.

24 VAC

HUMIDIFIER

24 VAC

HUMIDIFIER

HUMIDIFIER

PSO (4)

PS (10)

0

C

7

6

5

4

3

2

1

OFF = CONTROL FAILURE

STEADY ON = NORMAL OPERATION

1 FLASH =

2 FLASHES = PRESSURE SWITCH STUCK CLOSED

3 FLASHES = PRESSURE SWITCH STUCK OPEN

4 FLASHES = OPEN HIGH LIMIT

5 FLASHES = FLAME SENSE WITHOUT GAS VALVE

OPEN ROLLOUT OR OPEN FUSE

7 FLASHES = LOW FLAME SIGNAL

6 FLASHES =

SYSTEM LOCKOUT (RETRIES EXCEEDED)

CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY

CONTROL

MODULE

INTEGRATED

FUSE

HI

BR

OR

MVH (12)

FACTORY SETTINGS
SHOWN

TO 115VAC/ 1

Ø /60 HZ POWER SUPPLY WITH

GY

Y

6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN
STANDBY (NO THERMOSTAT INPUTS)

BK

LI

NE

NE

UTR

A

L

S

8

8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING

PU

GY

(HONEYWELL)

NO

C

C

PRESSURE SWITCH

FRONT COVER

NO

AUXILIARY LIMIT CONTROLS

HI

C

VALVE

GAS

PM

MVL(2)

ID BLOWER
PRESSURE

SWITCH

ON

OFF

2ND
STAGE
DELAY

MODE

HEAT
OFF
DELAY

FS

1

2

3

*

*

*

*

SEE
NOTE 6

COOL-H