beautypg.com

GE PT970SM User Manual

Pt970sm, 30" built-in double microwave/convection oven, For answers to your monogram

background image

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

ge.com or call GE Answer Center

®

service,

800.626.2000.

Listed by

Underwriters

Laboratories

Specification Revised 9/07

220145

CL

2 x 4 or

equivalent

runners

Suitable

bracing

to support

runners

21-5/8"

over centerline

of cabinet

(must support 275 lbs.)

Cabinet

30"

A – Overlap of oven over side of edges of cutout

11/16"

B – Overlap of oven at top and bottom of cutout

1"

C – Overall of oven at top of cutout

1/2"

Oven
D – Overall depth*

23-1/2"

E – Overall height with trim

44"

Overall height without trim

43-1/2"

E – Overall width

29-3/4"

*Depth including door handle is approximately 26-6/10" min. to

26-9/10" max.

20''

28''

21''

A

F

A

B

C

CONDUIT

(72'' LONG)

CUTOUT

HEIGHT

42-3/16'' MIN.

42-1/4'' MAX.

CUTOUT

WIDTH

28-1/2'' MIN.

28-5/8'' MAX.

Minimum

cutout location

21-5/8''

from the floor

21" Minimum

Door Allowance

JUNCTION BOX

LOCATION

CABINET

WIDTH

30''

DOOR MUST BE

REMOVED BEFORE

INSTALLATION

MOST 30'' WALL CABINETS CAN BE USED WITH THIS UNIT.

THE OPENING BETWEEN THE INSIDE WALLS MUST BE AT LEAST 28-1/2'' WIDE.

D

CUTOUT DEPTH

23-1/2'' MIN.

E

KW Rating

240V

6.4

208V 5.6

Breaker Size

240V

30 Amps

208V 30 Amps

Note: Cabinets installed adjacent to wall ovens
must have an adhesion spec of at least a 194°F
temperature rating.

Electric wall ovens are

not approved for installation with a plug and

receptacle. They must be hard wired in accordance

with installation instructions.
Door handle protrudes 3" from door face. Cabinets
and drawers on adjacent 45° and 90° walls should be
placed to avoid interference with the handle.
Installation Information: Before installing, consult
installation instructions packed with product for
current dimensional data.

PT970SM

GE Profile

30" Built-In Double Microwave/Convection Oven

CL

2 x 4 or

equivalent

runners

Suitable

bracing

to support

runners

21-5/8"

over centerline

of cabinet

(must support 275 lbs.)

Cabinet

30"

A – Overlap of oven over side of edges of cutout

11/16"

B – Overlap of oven at top and bottom of cutout

1"

C – Overall of oven at top of cutout

1/2"

Oven
D – Overall depth*

23-1/2"

E – Overall height with trim

44"

Overall height without trim

43-1/2"

E – Overall width

29-3/4"

*Depth including door handle is approximately 26-6/10" min. to

26-9/10" max.

20''

28''

21''

A

F

A

B

C

CONDUIT

(72'' LONG)

CUTOUT

HEIGHT

42-3/16'' MIN.

42-1/4'' MAX.

CUTOUT

WIDTH

28-1/2'' MIN.

28-5/8'' MAX.

Minimum

cutout location

21-5/8''

from the floor

21" Minimum

Door Allowance

JUNCTION BOX

LOCATION

CABINET

WIDTH

30''

DOOR MUST BE

REMOVED BEFORE

INSTALLATION

MOST 30'' WALL CABINETS CAN BE USED WITH THIS UNIT.

THE OPENING BETWEEN THE INSIDE WALLS MUST BE AT LEAST 28-1/2'' WIDE.

D

CUTOUT DEPTH

23-1/2'' MIN.

E

Dimensions and Installation Information (in inches)