beautypg.com

Alarm in, Alarm out, Record start in – GE DSR-1000eZ User Manual

Page 12: Alarm record reset

background image

Calibur DSR-1000eZ

1-6

0150-0238A

Alarm In

An alarm condition can be activated by an Active Low TTL input
or by relay contact devices such as pressure pads, passive
infrareds, door switches, or other similar devices.

Input: Active Low TTL w/ pull-ups
or Normally Open Relay.
High: 5V (12V tolerant)
Low: Ground

Minimum Duration: 0.5 Seconds

Figure 1-4 Normally Open Relay Alarm Connection

Pin 1

Pin 7 or 10

A l a r m I n p u t

G r o u n d

A c c e s s o r i e s P C B

T y p i c a l A l a r m D e v i c e

R e f e r t o e a c h a l a r m d e v i c e s ' s

m a n u a l f o r s p e c i f i c w i r i n g d e t a i l s .

N o r m a l l y O p e n

( C l o s e s D u r i n g A l a r m )

Alarm Out

The Alarm output is activated when a teletext alarm is detected,
or while the Alarm Input is active. The Alarm output is only
active for the duration of the alarm event.

Output: Active Low
High: 12V
Low: Ground
Current Out: 50mA Max
Short Circuit Protected.

Low for duration of alarm.

Record Start In

Record Start In will place the unit in Record mode when
activated. Compatible with the Disk End Out signal from a
second unit.

Input: Active Low TTL w/ pull-ups
or Normally Open Relay.
High: 5V (12V tolerant)
Low: Ground

Minimum Duration: 0.5 Seconds

Alarm Record Reset

This feature is for future development, and has not yet been implemented.