Friedrich CP06E10 User Manual
Page 21
21 Room Air Conditioner
Troubleshooting Guide
Fails to Start
Improper thermistor
setting
Loose terminal
connection
Improper wiring
Check of power source.
Drop of power voltage.
Capacitor check.
Replacement.
Check of control panel
setting.
Compressor fails only to
start.
Defect of compressor
capacitor.
Replacement of compressor
(Motor damaged).
Irregular motor insulation (
Ω
)
Irregular motor resistance (
Ω
)
Check of circuit breaker
and fuse.
Check control panel.
Fan only fails to start.
Improper wiring.
Defect of fan motor
capacitor.
Replacement of fan motor.
Regular but fails to start.
Replacement of compressor.
(Locking of piston, metal.)
Irregular motor
resistance (
Ω
)
Irregular motor
insulation (
Ω
)
This manual is related to the following products:
See also other documents in the category Friedrich Conditioners:
- Kuhl Series 12000 BTU Smart Window Air Conditioner Warranty (56 pages)
- Kuhl Series 12000 BTU Smart Window Air Conditioner Warranty (43 pages)
- Kuhl Series 12000 BTU Smart Window Air Conditioner Warranty (58 pages)
- Kuhl Series 12000 BTU Smart Window Air Conditioner Warranty (59 pages)
- Kuhl Series 12000 BTU Smart Window Air Conditioner Warranty (24 pages)
- Kuhl Series 12000 BTU Smart Window Air Conditioner Warranty (62 pages)
- Kuhl Series 12000 BTU Smart Window Air Conditioner Warranty (43 pages)
- Kuhl Series 12000 BTU Smart Window Air Conditioner Warranty (16 pages)
- Kuhl Series 23,000 BTU Smart Window Wall Room Air Conditioner Warranty (54 pages)
- ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Warranty Guide (56 pages)
- ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Warranty Guide (28 pages)
- ZoneAire Series 14,500 BTU Smart Packaged Terminal Air Conditioner Installation Guide (36 pages)
- ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Warranty Guide (72 pages)
- P/N9368987060-01 (18 pages)
- CP08F10 (29 pages)
- ES12 (56 pages)
- Hazardgard Series 19,000 BTU Commercial Room Air Conditioner Warranty (16 pages)
- Hazardgard Series 19,000 BTU Commercial Room Air Conditioner Warranty (16 pages)
- MR09C1H (28 pages)
- HEAT&COOLING MODEL INVERTER (REVERSE CYCLE) ROOM AIR CONDITIONER WALL MOUNTED TYPE (50 pages)
- MW18Y3H (28 pages)
- 2009 (44 pages)
- CP10F10 (28 pages)
- MR24Y3F (24 pages)
- 1883 (2 pages)
- CP24 (16 pages)
- A Series / 24 (8 pages)
- M36CF (2 pages)
- PDXDEA (5 pages)
- P12A (12 pages)
- MR12C1F (17 pages)
- MS36Y3F (25 pages)
- 115 Volts US10 (61 pages)
- P12B (12 pages)
- EQ08L11A (2 pages)
- ES12M33 (132 pages)
- KP05A10 KP06A10 (27 pages)
- MW24Y3H (52 pages)
- CP05 CP Line (43 pages)
- CP06/CP08 (59 pages)
- MW18C3F (50 pages)
- MR36C3F (24 pages)
- ZQ08A10C (28 pages)
- KS10 (24 pages)