4 installing the display unit, 1 desktop, overhead mounting – Furuno SC-60 User Manual
Page 28
2. INSTALLATION
2-14
2.3.4
Adjusting for orientation error
It may be impossible to perfectly align the processor unit on the fore-and-aft or
port-and-starboard line. Open the top cover, loosen the two fixing screws on the
angular rate sensor and turn. For example, if the orientation error is 2.5
°
to port,
rotate the sensor 2.5
°
starboard
.
The range of adjustment is -45
°
to +45
°.
Close
the top cover after completing the adjustment.
Scale
Reference
Direction
Processor Unit
Bow-stern, Port-starboard
direction
Bulkhead Mounting
Plate
Fixing Screw
Hole on processor unit
Graduation, every
2.5
°
Angular rate sensor, top view
2.4
Installing the Display Unit
2.4.1
Desktop, overhead mounting
1. Fasten the hanger to the mounting location with four tapping screws
(supplied). See the outline drawing for mounting dimensions.
2. Screw the knobs into the display unit.
3. Set display unit to the hanger and tighten the knobs.
4. Run the ground wire between the ground terminal on the display unit and the
ship’s superstructure.
Desktop
Overhead
Display unit mounting methods