2. INSTALLATION


2-14

2.3.4

Adjusting for orientation error

It may be impossible to perfectly align the processor unit on the fore-and-aft or
port-and-starboard line. Open the top cover, loosen the two fixing screws on the
angular rate sensor and turn. For example, if the orientation error is 2.5

°

to port,

rotate the sensor 2.5

°

starboard

.

The range of adjustment is -45

°

to +45

°.

Close

the top cover after completing the adjustment.

Scale

Reference
Direction

Processor Unit

Bow-stern, Port-starboard
direction

Bulkhead Mounting
Plate

Fixing Screw

Hole on processor unit

Graduation, every
2.5

°

Angular rate sensor, top view

2.4

Installing the Display Unit

2.4.1

Desktop, overhead mounting

1. Fasten the hanger to the mounting location with four tapping screws

(supplied). See the outline drawing for mounting dimensions.

2. Screw the knobs into the display unit.
3. Set display unit to the hanger and tighten the knobs.
4. Run the ground wire between the ground terminal on the display unit and the

ship’s superstructure.

Desktop

Overhead

Display unit mounting methods