beautypg.com

Owner’s manual, Installation, Installation and clearances – FMI VFP18MV User Manual

Page 7: Check gas type, Vent-free operation only), Log sizing requirements

background image

7

105071

OWNER’S MANUAL

INSTALLATION AND
CLEARANCES

(Vent-Free Operation Only)

WARNING: Maintain the mini-

mum clearances. If you can, pro-
vide greater clearances from
floor, ceiling, and adjoining wall.

INSTALLATION

WARNING: A qualified ser-

vice person must install heater.
Follow all local codes.

WARNING: Before installing

in a solid fuel burning fireplace,
the chimney flue and firebox must
be cleaned of soot, creosote,
ashes and loose paint by a quali-
fied chimney cleaner. Creosote
will ignite if highly heated. A dirty
chimney flue may create and dis-
tribute soot within the house. In-
spect chimney flue for damage. If
damaged, operate heater with flue
damper closed.

WARNING: Seal any fresh air

vents or ash clean-out doors lo-
cated on floor or wall of fireplace.
If not, drafting may cause pilot
outage or sooting. Use a heat-
resistant sealant. Do not seal
chimney flue damper.

WARNING: Never install the

heater
• in a bedroom or bathroom un-

less installed as a vented ap-
pliance, see page 10

• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the heater

• in high traffic areas
• in windy or drafty areas

CAUTION: This heater creates

warm air currents. These currents
move heat to wall surfaces next to
heater. Installing heater next to
vinyl or cloth wall coverings or
operating heater where impurities
(such as tobacco smoke, aromatic
candles, cleaning fluids, oil or
kerosene lamps, etc.) in the air
exist, may discolor walls.

IMPORTANT:

Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation
, pages 4 through 6.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply is
not propane/LP, do not install heater. Call dealer
where you bought heater for proper type heater.

NOTICE: State or local codes may
only allow operation of this appli-
ance in a vented configuration.
Check your state or local codes.

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

LOG SIZING REQUIREMENTS

Minimum Firebox Size

Log

Front

Rear*

Size Height Depth Width Width
18"

17"

14"

20"

14"

24"

17"

14"

26"

18"

30"

17"

14"

32"

22"

Continued

*Measured at 14" depth

MINIMUM FIREPLACE

CLEARANCE TO

COMBUSTIBLE MATERIALS

Log Size

18", 24", 30"

Side Wall

16"

Ceiling

42"

Floor

5"

Carefully follow the instructions below. This
will ensure safe installation into a masonry,
UL127-listed manufactured fireplace, or
listed vent-free firebox.

Minimum Clearances For Side
Combustible Material, Side Wall,
and Ceiling

A. Clearances from the side of the fire-

place cabinet to any combustible ma-
terial and wall should follow the dia-
gram in Figure 4.

Example:

The face of a mantel, book-

shelf, etc. is made of combustible ma-
terial and protrudes 3

1

/

2

" from the wall.

This combustible material must be 4"
from the side of the fireplace opening
(see Figure 4).

Note:

When installing your gas logs

into a manufactured firebox, follow
firebox manufacturer’s instructions for
minimum clearances to combustible
materials.

B. Clearances from the top of the fireplace

opening to the ceiling should not be less
than 42 inches.

Figure 4 - Minimum Clearance for
Combustible to Wall

.5

2

7/16

7/8

1

3

/

4

3

1

/

2

5

1

/

4

7

8

3

/

4

10

1

/

2

12

1

/

4

1

4

6

8

10 12 14

16

FIREBOX

INCHES

INCHES

*Minimum 16 inches from Side Wall

*

Example

This manual is related to the following products: