Window Installation (on some models)
NOTES:
�
Handle air conditioner gently.
�
Be sure your air conditioner cabinet does not fall out of the
opening during installation or removal.
�
The place where the power cord exits the air conditioner
should be no more than 4 ft (122 cm) from a grounded
3 prong outlet.
�
Do not block the louvers on the front panel.
�
Do not block the louvers on the outside of the air conditioner.
Attach Top Channel
NOTE: Attach top channel and side curtains to air conditioner
cabinet before placing cabinet in window.
1. Locate provided bag of screws.
2. Place top channel on top of air conditioner cabinet, lining up
the 4 holes in top channel with the 4 holes on top of air
conditioner cabinet.
3. Using 4 - #10 x ³⁄₈" washer-head Phillips thread-cutting
screws, attach top channel to air conditioner cabinet.
Attach Side Curtains
1. Locate provided bag of screws.
2. Insert top and then bottom of right-hand curtain housing in
top and bottom curtain channels on air conditioner.
Top view
Bottom view
3. Extend right-hand curtain outward so you may insert the
first screw through the middle hole of the curtain. Using #10 x
¹⁄₄
" pan-head Phillips screw, screw curtain to middle hole in
air conditioner cabinet.
NOTE: This screw is required to correctly attach curtain (top
to bottom) to the air conditioner cabinet.
4. While the right-hand curtain is still extended, insert #10 x ¹⁄₄"
pan-head Phillips screws into the top and bottom slots of
curtain. Screw curtain to the top and bottom holes in the air
conditioner cabinet.
5. Slide the curtain housing into the curtain channels as far as it
will go.
6. Repeat above steps for the left-hand curtain.
Attach foam adhesive seal
Attach foam adhesive seal along the bottom of the curtain
bottom channel.
A. Top channel
B. #10 x
³⁄₈
" washer-head Phillips thread-cutting screws
A. Curtain housing
B. Curtain top channel on air conditioner
A
B
A
B
A. Curtain housing
B. Curtain bottom channel on air conditioner
A. Curtain housing
B. Foam adhesive seal
A
B
A
B
- WallMaster Series 12000 BTU Thru-the-Wall Smart Air Conditioner Warranty WallMaster Series 11600 BTU Thru-the-Wall Smart Air Conditioner Warranty WallMaster Series 8000 BTU Smart Thru-The-Wall Air Conditioner Warranty KS15 EM24 ES16 EM18 EL36 ZQ07 ZQ05 CP12 P012A P012B ZStar CP06 D30C D40C D65C CP08 ZQ10 ZQ08 Chill Premier Series Slide-Out Chassis Smart Room Air Conditioner Warranty Kuhl Series 28000 BTU Window Air Conditioner Warranty Chill Premier Series Slide Out Chassis Smart Window Air Conditioner Warranty Chill Premier Series Smart Window Air Conditioner Warranty ZoneAire Series 11,000 BTU Smart Portable Air Conditioner Warranty ZoneAire Series Single Hose Smart Portable Air Conditioner Warranty ZoneAire Series 12,000 BTU Dual Hose Smart Portable Air Conditioner Warranty Kuhl Series 23,000 BTU Smart Window Wall Room Air Conditioner Warranty Kuhl Series 12000 BTU Smart Window Air Conditioner Warranty