beautypg.com

Friedrich MR12Y3H User Manual

Page 12

background image

11

E R R O R D E T E C T I O N

Error

Operation
LED

Coil dry
LED

Timer LED

Serial signal error

Off

2 flash

off

off

off

off

off

off

off

off

off

off

off

off

off

off

off

off

off

off

off

off

3 flash

4 flash

5 flash

Serial signal (reverse) error, at operation start up

Serial signal (reverse) error, during oeration

Serial signal (forward) error, at operation start up

Serial signal (forward) error, during operation

8 flash

Wired remote control error

Indoor unit
thermistor error

2 flash

2 flash

Outdoor unit
thermistor error

3 flash

3 flash

2 flash

3 flash

4 flash

Indoor unit control error

4 flash

Indoor unit LED

Wired

remote

control

Error

Outdoor unit
control error

5 flash

2 flash

3 flash

5 flash

Indoor fan motor error

6 flash

CT abnormal

Outdoor unit fan drive system abnormal

2 flash

Refrigerant cycle error

7 flash

3 flash

Optional function error

Model information error

8 flash

0.1 sec on/off 0.1 sec on/off 0.1 sec on/off

6 flash

01

01

13

13

00

02

04

0C

06

0A

17

18

1A

11

2 flash

3 flash

Abnormal lock (upper fan motor)

Abnormal rotation (upper fan motor)

12

12

0F

24

1B

Current trip error

Outdoor air thermistor error

Indoor air thermistor error

Heat exchanger thermistor error

Heat exchanger middle thermistor error

Discharge pipe thermistor error

2 flash

20

Manual auto button welded

Compressor location detection error

Model information error

Discharge temperature abnormal

Cooling high pressure abnormal rise

off

off

2 flash

3 flash

19

19

Active filter abnormal (first time)

Active filter abnormal (second time)

4 flash

25

PFC circuit error