)XQFWLRQVRIWKH.H\SDGV

1. DISPLAY WINDOW.

Alpha Display Keypads: 2-line, 32-
character Liquid Crystal Display (LCD)
keypads that display protection point
identification, system status, and messages.

Fixed-Word Display Keypads: Display
protection zone ID and system status
messages using pre-designated words in the
LCD display.

2.

1

OFF

Disarms burglary portion of the

system, silences alarms and audible trouble
indicators, and clears visual display after
problem's correction.

3.

2

AWAY

Arms the entire burglary system,

perimeter and interior.

4.

3

STAY

Arms perimeter portion of burglary

system only. Interior protection is not armed,
allowing movement within premises without
causing an alarm.

5.

5

TEST

Tests the system and alarm

sounder if disarmed. Refer to Testing The
System
section for test procedures.

6.

6

BYPASS

Removes individual protection

zones from being monitored by the system.

7.

9

CHIME

Turns CHIME mode on and off.

When on, the opening of windows or doors
while the system is disarmed will sound 3
beeps at the keypad(s).

8.

#

This key can be used for "Quick

Arming" of the system without use of a
security code (if programmed).

9.

8

CODE

Used to assign additional user

codes for other users of the system.

10. KEYS 0–9: Used to enter your security

code(s) and to perform their associated
system functions after the security code has
been entered.

11.

7

INSTANT

Arms in manner similar to the

STAY mode, but without the entry delay
feature. Entering via an entry/exit door will
cause an alarm.

12.

READY

Used to display all open protection

zones.

13. FUNCTION KEYS: Keys A, B, C, D may

have been programmed for a variety of
functions, including panic (emergency)
functions. For details, see the Function Keys
section.

14.

4

MAXIMUM

Arms the entire burglary

system, perimeter and interior, but without
entry delay feature. Entering via an
entry/exit door will cause an alarm.

15. INTERNAL SOUNDER: The built-in

sounder mimics the alarm sounder during
alarms, and will also "beep" during certain
system functions.

16. READY INDICATOR: (GREEN) Lit when

the system is ready to be armed (no faults
present). While the system is disarmed, this
indicator will go on and off as protection
zones are closed and opened.

17. ARMED INDICATOR: (RED) Lit when the

system has been armed.