2 replacement of fuse, battery, 3 simple troubleshooting, Caution – Furuno GP-1650WDF User Manual
Page 94

13. MAINTENANCE & TROUBLESHOOTING
13-2
13.2 Replacement
of
Fuse,
Battery
The fuse on the power cable protects the 
system from reverse polarity of the ship’s 
mains and equipment fault. If the fuse blows, 
find the cause before replacing it. Use only a 
3 A fuse. Using the wrong fuse will damage 
the unit and void the warranty. 
Use the correct fuse.
Use of a wrong fuse can cause fire or 
damage the equipment.
CAUTION
A battery installed on the circuit board inside 
display unit preserves data when the power 
is turned off. The life of the battery is about 
three years. When the battery voltage is low 
the battery icon (
) appears on the display.
When this happens, contact your dealer to 
request replacement of the battery. 
Type
Code
Number
Lithium 
Battery 
CR2450-F2 ST2L
000-144-941
 
Note : Use only the specified battery. Use of 
an incorrect battery may cause 
explosion. Dispose of the battery in 
accordance with local regulations. 
13.3 Simple
Troubleshooting
Below are simple troubleshooting 
procedures which the user can follow to 
restore normal operation. 
 
Simple troubleshooting (plotter)
If …
Then …
check for blown fuse.
check that the power connector is firmly tightened.
check for corrosion on power cable connector.
check for damaged power cable.
you cannot turn on the power
check ship’s battery for proper voltage output (12/24 V).
power is on but nothing appears
press the [POWER/BRILL] key and then the cursor pad 
to adjust display brilliance and tone. 
there is no response when a key is pressed
turn on the power again.
check for loosened antenna connector.
position is not fixed within 90 seconds.
check GPS receiver status indication.
track is not plotted
plotting is stopped. (“H” appears on the plotter display.)
bearing is wrong
check that correct magnetic variation is entered on the 
DISPLAY OPTIONS menu. 
loran or Decca TDs do not appear
check that proper Loran or Decca chain codes are 
entered on the DISPLAY UNIT. 
loran TDs are wrong
enter TD offset on the GPS/DGPS/TD OPTIONS menu.
ship’s speed display is not zero after ship is stopped
try to decrease GPS speed smoothing setting on the 
GPS/DGPS/TD OPTIONS menu. 
