Specifications, Thd specifications of thd satellite compass sc-50 – Furuno Sc 50 User Manual
Page 9
SP - 1
E7251S01B
THD SPECIFICATIONS OF THD SATELLITE COMPASS
SC-50
1 GENERAL
1.1 Heading Accuracy
±1.0° (95%)
1.2 Heading
Resolution 0.1°
1.3 Follow-up
45°/s
rate-of-turn
1.4 Settling Time
3 minutes
1.5 Position Accuracy
10 m, or 5 m (DGPS), 95% of the time
1.6 Heading/Nav Data Output
AD-10 format: 1 port (specialty port)
AD-10 format 5 ports or IEC 61162 format 10 ports
(selectable on menu)
IEC 61162 format is RS-485 level
Sentence: HDT, HDM, ROT, ATT, VDR, VTG, GGA, GNS
GLL, VHW, VBW, HVE, ZDA
1.7 Log Signal Output
1 port, log pulse (pulse signal)
1.8 Heading Alarm Output 1 port, alarm output (contact signal)
1.9 Motion Output Signal
1 port pitch, 1 port roll
1.10 External Heading Input 1 port AD-10 or IEC61162 format (auto recognition)
AD-10: backup heading
IEC 61162: water tracking speed input (sentence: HDT, HDG,
HDM, VBW, VHW, VLW)
1.11 External Beacon Input 1 port, RTCM SC-104 format (RS-232 level)
2 DISPLAY
UNIT
2.1
Display Type
4.5 inch monochrome LCD, 120 x 64 dots
2.2
Effective Area
60 mm (H) x 95 mm (W)
2.3
Contrast 64
levels
2.4
Display Mode
Heading, Nav data, Steering, Compass rose, Rate of turn and
Speed modes
3 POWER
SUPPLY
12-24 VDC: 1.2-0.5 A
4
ENVIRONMENTAL CONDITIONS AND EMC
4.1 Ambient
Temperature
Display/Processor Unit -15°C to +55°C, Designed for protected area
Antenna Unit
-25°C to +70°C, Designed for exposed area
4.2 Humidity
93% ±3% at 40°C