INSTALLATION

Continued

Decide which way you intend to gain access
into the bottom rear of the firebox to install
the blower accessory. The lower front panel
can be removed easily by snapping out the
front with a flat blade screwdriver. Use cau-
tion not to scratch any surfaces. Models with
louvered front panels can also be removed by
inserting fingertips between slots and gently
pulling out. DO NOT FORCE. The panels are
actually held in place by means of a retention
dimple embossed on the edge of removable
panels.
Accessibility to the bottom on 36" and 42"
models only, can also be gained through the
access panel underneath the bottom front
refractory brick liner. Lift the bottom front
refractory brick liner up and out of the firebox
floor, exposing the rectangular shaped access
panel (see Figure 11, page 13). The sides and
back refractory brick liner pieces do not have
to be removed. Lift access panel out by using
finger holes. Blower accessory BK or BK3 can
now be installed.

warninG: if there is a duplex

electrical outlet installed in the

right side of the bottom of the

fireplace base area (see figure

12), be sure that the electrical

power to the outlet is turned off

before proceeding with blower

installation. failure to do this

may result in serious injury.

model bk Installation
1. Attach the power cord to blower motor by

firmly pushing two female terminals at end
of power cord onto two spade terminals
on blower motor (see Figure 13).

2. Attach green ground wire from power cord

to blower housing using screw provided
(see Figure 13). Tighten screws securely
with a phillips screwdriver.

3. Place blower against lower rear wall of

firebox outer wrapper with exhaust port di-
rected upward. Depending on your model,
you may have to carefully route the blower
assembly past controls and brackets and
position blower inside back opening. The
blower will be held in position against the
back wall by magnets incorporated onto
blower housing (see Figure 13).

4. Be certain that all wire terminals are

securely attached to terminals on blower
motor and that the screw retaining the
green ground wire is tight.

5. Position speed control bracket over flange

on hearth pan by sliding it up between
firebox face and hearth pan flange, then
down until seated onto lower flange of lou-
ver opening (see Figure 14, page 15).

6. Mount speed control box by placing plas-

tic control shaft through bottom hole on
speed control bracket. Top screw head
on control box will fit inside top hole on

Duplex Electrical Outlet

Figure 12 - Accessing Duplex Electrical
Outlet Installed in Bottom Right Side of

Firebox

Figure 13 - Blower Model BK

Magnetic Strips
Exhaust
Port

Screw

Green
Ground
Wire

Spade
Terminals

Side View
Firebox Bottom

Air Flow
Direction

Blower
Installed
After
Lower
Panel
Removed

Blower
Location Magnets