Installing/Removing the Fan Module
Fan Module
6.1
Installing/Removing the Fan Module
I
Please note the status of the fan LED before removing and after installing
the fan module (3) (see section “Fan LED” on page 23).
Floorstand model
Ê
Remove the left side cover (see section “Removing/Mounting the left Side
Cover” on page 26).
Rack model
Ê
Loosen the two knurled screws on the front of the rack model and pull out
the storage subsystem from the rack.
Figure 13: Releasing and Removing the Fan Module
Ê
Release the fan module by putting two fingers into the recessed grips and
push the locking mechanisms found here inwards (1).
V
CAUTION!
Note the warning label “Rotating Parts“ (4) on the fan module. There
is an increased risk of injury from rotating parts.
Ê
Remove the fan module from the storage subsystem in the direction of the
arrow (2).
3
1
1
2