C. clearances – Heatiator CB4842IR User Manual
Page 18

Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09
8
0 in.
C
B
A
Note: All pipe clearance
specifications are per vent
manufacturer's installation
instructions.
0 (Clearance to
Standoffs)
30 in.
(762 mm)
clearance to ceiling
1/2 in. (13 mm)
1/2 in.
(13 mm)
Drywall
0 in.
Per Vent
Manufacturer’s
Specifications
Combustible flooring may be installed
next to the front of the appliance.
Combustible Object
36 in.
(914 mm)
A
Rough Opening
(Width)
B
Rough Opening
(Height)
C
Rough Opening
(Depth)
in.
42
38-3/4
23-1/2
mm
1,067
984
597
in.
48
38-3/4
23-1/2
mm
1,219
984
597
CB4236I
CB4842I
Model
Figure 5.2 Clearances to Combustibles
C. Clearances
WARNING! Risk of Fire! Maintain specified air space
clearances to appliance and vent pipe:
• Insulation and other materials must be secured to
prevent accidental contact.
• The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with fireplace or chimney.
• Failure to maintain airspace may cause overheating and
a fire.
Note: If the inside of the framed cavity is to be finished,
the framing dimensions must include the finished surface.
Example: If drywall is to be attached to the rear wall, the
depth must be measured from the drywall surface.
Note: The appliance must be raised 1 1/4 in. (32 mm) off floor so
the Harbor System can be used. Adjust framing and vent locations
accordingly.
NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth.
DO NOT install directly on
carpeting, vinyl, tile or any combustible material other than
wood.