beautypg.com

Wwarning, Connecting electric dryers (cont.) usa only – LG Signature Series TurboSteam Series 29 Inch Electric Smart Dryer Owners Manual User Manual

Page 30

background image

30

Connecting Electric Dryers (cont.)
USA only

W

WARNING

t$POOFDUUIFQPXFSDPSEUPUIFUFSNJOBMCMPDL

$POOFDUFBDIQPXFSDPSEXJSFUPUIFUFSNJOBMCMPDL
TDSFXUIBUIBTUIFTBNFDPMPSFEXJSF'PSFYBNQMF
DPOOFDUUIFCMBDLQPXFSDPSEXJSFUPUIFUFSNJOBM
CMPDLTDSFXXJUIUIFCMBDLXJSF'BJMVSFUPGPMMPX
UIFTFJOTUSVDUJPOTNBZSFTVMUJOBTIPSUPWFSMPBE

fire or death.

t(SPVOEJOHUISPVHIUIFOFVUSBMDPOEVDUPSJT

QSPIJCJUFEGPS OFXCSBODIDJSDVJUJOTUBMMBUJPOT
NPCJMFIPNFT SFDSFBUJPOBMWFIJDMFTBOE
BSFBTXIFSFMPDBMDPEFTQSPIJCJUHSPVOEJOH
UISPVHIUIFOFVUSBMDPOEVDUPS

Three-wire connection for electric dryers: Direct wire

t"XJSFDPOOFDUJPOJT/05QFSNJUUFEPOOFX

construction after January 1, 1996.

t"6-MJTUFETUSBJOSFMJFGJTSFRVJSFE

1. Remove 3

1

⁄2 inches (8.9 cm) of the outer covering from

the wire. Strip 1 inch (2.5 cm) insulation from each

XJSF#FOEUIFFOETPGUIFUISFFXJSFTJOUPBIPPL

shape.

2. Remove the terminal block access cover on the upper

back of the dryer. Install a UL-listed strain relief into
the power cord through-hole; then thread the power
cable prepared in Step 1 through the strain relief.

t6TF6-MJTUFEXJSF"8(NJOJNVNDPQQFS

conductor cable.

t"MMPXBUMFBTUGU NMFOHUIUPBMMPXGPSSFNPWBM

and reinstallation of the dryer.

3. Attach the two hot leads of the power cord to the

outer terminal block screws. Attach the neutral wire to
the center terminal block screw. Connect the external
ground (if required by local codes) to the green
ground screw.

5*()5&/"--4$3&844&$63&-:

.

Reinstall the terminal block access cover.

1" (2.5 cm)

UL-Listed
Strain Relief

UL-Listed 3-Wire
Power Cord

Terminal

#MPDL

Ground
Screw

Neutral

(White)

Hot

#MBDL

Hot

(Red)

External Ground
Wire (If required
by local codes)

White Wire
from Dryer
harness

INSTALLATION