Output Measurement

A sample of input LED signals and various output waveforms are captured and shown in Figure 6. The default setup

connection is adopted, but with Q1a and Q1b switchers mounted. The switchers have a gate capacitance equivalent to

10 nF.

Figure 6. Input LED signals and switchers’ gate voltage waveforms

Note: Both IN1+ and IN2+ are set at 49% duty ratio.

Figure 7 shows the turn-off gate signal of Q1a and the turn-on gate signal of Q1b:

Figure 7. Turn-off and Turn-on Gate waveforms of Q1a and Q1b