Air Tightness Requirements for Assemblies

Table 17: Air tightness requirements for Assemblies

Standard

Region

Comments

Requirement

ACH50

n

50

CFM

75

/sq ft

(m

3

/hr)

50

/m

2

North America

Canadian NBC for RH

Canada

0.1

(L/s 50)/m

2

0.26

0.02

0.28

National Canadian Building
Code

Canada

Assemblies

0.15

(L/s 50)/m

2

0.33

0.025

0.35

Comparison of different Air Leakage Results for the same enclosure

Table 18: Comparison of different units for a house 50 x 30 x 20 feet, with n=0.65; proposed units are highlighted

Result

Units

Application

1,191

CFM50

House leakage in the US

1,550

CFM75

Large building leakage in the US

0.397

CFM50/sq ft

House and duct leakage in the US

0.253

CFM50/sq ft

House and duct leakage in the US, MLR

0.192

CFM50/sq ft

House and duct leakage in the US

0.250

CFM75/sq ft

Large building leakage in the US

0.249

(CFM @ 0.3 in WC)/sq ft

Large building leakage in the US

66

sq in EfLA4

House leakage in the US

1.06

sq in EfLA4/100 sq ft

Environmental Tobacco Smoke - apartment leakage in the US

123

sq in EqLA10

House leakage in Canada and US

157

sq in EqLA50

1.98

sq in EqLA10/100 sq ft

2.53

sq in EqLA50/100 sq ft

2.38

ACH50, n

50

Proposed for houses and large buildings worldwide

0.000107

SLA, sq in EfLA50/ sq in

House leakage in WA state must be 0.00030 or less

107

EfLA50/10

6

sq in

175

EqLA50/10

6

sq in (surface area)

Proposed for all buildings

0.56

Q50, m

3

/s

Large building leakage in Europe

196

V

4 ,

m

3

/h

All building leakage in France

2,023

V

50 ,

m

3

/h

Large building leakage in Europe