E

AIR FLOW

Move the air vent directly to adjust the air flow direction of the horizontal louvres.

F

EMPTY INTERNAL WATER CONTAINER

In extreme (environmental) circumstances it may be necessary to empty the
internal water container regularly. When the internal water container is full
the light will flash and the unit will beep continously. The unit will switch off
automatically. To empty the water container do the following:

1 Do not move the unit. Drastic movements can cause water leakage.

2 Switch off the unit and remove the plug from the wall outlet.

3 Place a pan or appropriate tray on the floor underneath the permanent drain

tube.

4 Remove the rubber plug 8 from the drain tube and let the water run out.

(± 0.5 litres).

5 Replace the rubber plug 8, put the plug into the wall outlet, and switch on

the unit. The warning light

should be off.

G

NOTE!

When the air conditioner is in use, under normal circumstances the
condensed water will be drained through the air outlet-tube.

G

CONTINUOUS DRAINAGE

1 Switch off the unit and remove the plug from the mains.

2 Place a pan or appropriate tray on the floor underneath the permanent drain

tube to collect any water draining away.

3 Remove the rubber plug 8 from the drain tube.

4 Connect a drain hose (ø 15 mm) into the water outlet and extend with extra

water tube as needed.

5 Place the other end of the drain tube at a location suitable for the purpose (a

drain hole, for instance). In doing so, take care to ensure that the tube is not
twisted and is free of kinks.

NOTE!

The tube must be placed so as to be declining along its entire length.