Related parameters and functions, 2 output voltage pid, 1 1rw 9lhzdeoh < 9lhzdeoh$ydlodeoh – Yaskawa PID A1000 User Manual
Page 7
2 Output Voltage PID
YASKAWA TM.A1000SW.061 Output Voltage PID A1000 Custom Software Supplement
7
Related Parameters and Functions
The legend below is used in this section to indicate which parameters are available in which control modes.
The parameter tables in this section are used to set up the drive for operation with the software.
Table 2 Modified Parameters
Table 3 Additional Parameters
No.
MEMOBUS/
Modbus
Address
Name
Digital Operator Display
Description
Range
Default
Value
Change
During
Run
Control Method/
Access Level
A1-02
0102h
Control Method
Control Method
Sets the control method.
0: V/Hz
1: V/Hz w/PG
2: Open Loop Vector
3: Flux Vector
4: PM VVC1
5: PM OLV
6: PM CLV
0 to 6
0
No
YYYYYYY
H3-06
0414h
Terminal A3 Function Selection
Terminal A3 Sel
Selects the function of the Terminal A3 Multi-
Function Analog Input.
0: Freq Ref Bias
1: Freq Ref Gain
. . .
20: Output V Fdbk
21: V Setpoint
0 to 21
20
No
YYYYYYY
n9-10
05D9h
Automatic Voltage Regulator Time
AVR Time
The AVR modifies output voltage based on bus
voltage.
0.0 to 100.0
5.0 ms
No
– – – – – – Y
n9-14
05DDh
Power Factor Angle Filter 1
Pwr Angle Flt 1
Sets the response of the power factor angle filter.
0 to 1000
10 ms
No
– – – – – – Y
n9-15
05DEh
Power Factor Angle Filter 2
Pwr Angle Flt 2
Sets the response of the power factor angle filter.
0 to 1000
10 ms
No
– – – – – – Y
No.
MEMOBUS/
Modbus
Address
Name
Digital Operator Display
Description
Range
Default
Value
Change
During
Run
Control Method/
Access Level
P1-01
0600h
Output Voltage Setpoint
Output V Setpt
Sets the voltage that the output voltage regulator
will try and seek if H3-02, H3-06 and H3-10 are
not set to "21".
0.0 to 600.0
460.0 Vac
Yes
– – – – – – Y
P1-02
0601h
Output Voltage PID Gain
Output V Gain
Sets the responsiveness of the output voltage
regulator.
Higher = more responsive
0.0 to 25.00
1.00
Yes
– – – – – – Y
P1-03
0602h
Output Voltage PID Integral Time
Output V I Time
Sets the responsiveness of the output voltage
regulator.
Lower = more responsive
0.00 to 360.00
1.00 sec
Yes
– – – – – – Y
± ± ±
<
± ±
<
&/930
2/930
$2/930
&/9
2/9
9) Z 3*
9I
1 1RW 9LHZDEOH
< 9LHZDEOH$YDLODEOH
±
1RW $YDLODEOH
&RQWURO 0HWKRG $FFHVV /HYHO 'HFRGLQJ