SMART TRAC DeviceNet Card

4

••

Smart Trac DeviceNet Card Technical Manual 3554-0070

Specifications

16 MHz V40 microprocessor with 128 Kbytes RAM

Software configurable interrupts 2, 5 and 7 (7 normally used)

DeviceNet compatible 5-pin connector

Network status bicolor indicator

Operating temperature 32° to 104°F (0° to 40° C)

Storage temperature -4° F to 140°F (-20° to 60° C)

Operating Humidity 5% to 90% non-condensing

Supports standard DeviceNet baud rates of 125, 250 and 500 baud

UCMM capable and supports Group 1, 2, and 3 dynamic connections.

Accepts shielded twisted pair cable compatible with target network

Quick Start

1. Check DIP switch settings on the card against the default settings (see

“Default Settings"). You should use default settings except in only
unusual situations. Your Smart Trac Field Engineer can help you if you
need assistance.

2. Power OFF your Smart Trac AC1.

3. Install the card in your Smart Trac AC1 in a PC/104 option card

position (on top of the Smart Trac Ethernet Card or another PC/104
option card).

4. Connect the DeviceNet network cable.

5. If your power supply is not on a common circuit breaker with the Smart

Trac AC1, power up your DeviceNet network.

6. Power up your Smart Trac AC1.

7. Test your card installation.