All Stop (F2) Command
The ALL STOP command is issued to set all or a specific part of the
switcher to a known state. The command causes the following functions to
occur:
•
Any ongoing KEY MIX is stopped,
•
An ongoing AUTO TRAN (Transition) is stopped,
•
An ongoing EFF DIS (Effects Dissolve) is stopped,
•
An ongoing SEQ (Sequence) is stopped,
•
The lever arms are set to a limit,
•
The transition type is set to MIX,
•
The transition mode is set to BKGD,
•
All Keys are removed,
•
Stop Effect Run, and
•
The Source selections remain unchanged.
Kalypso Effects Addresses
Valid effects addresses used by Kalypso systems for the All Stop command
are defined in
.
Table 97. All Stop Command
Function
Byte Count
Effects Address
Command Code
Message
Write
03
EX
F2
FF
Table 98. Kalypso Effects Addresses - All Stop Command
Effects Address
Assignment
00 PGM-PST
01
Mix/Effects 1
02
Mix/Effects 2
03
Mix/Effects 3
04
PGM-PST Secondary Partition
a
a
New effects address assignment associated with Kalypso.
05
Mix/Effects 1 Secondary Partition
06
Mix/Effects 2 Secondary Partition
07
Mix/Effects 3 Secondary Partition
0B