88

Switcher Products — Protocols Manual

Section 2 — Editor Protocol

All Stop (F2) Command

The ALL STOP command is issued to set all or a specific part of the
switcher to a known state. The command causes the following functions to
occur:

Any ongoing KEY MIX is stopped,

An ongoing AUTO TRAN (Transition) is stopped,

An ongoing EFF DIS (Effects Dissolve) is stopped,

An ongoing SEQ (Sequence) is stopped,

The lever arms are set to a limit,

The transition type is set to MIX,

The transition mode is set to BKGD,

All Keys are removed,

Stop Effect Run, and

The Source selections remain unchanged.

Kalypso Effects Addresses

Valid effects addresses used by Kalypso systems for the All Stop command
are defined in

Table 98

.

Table 97. All Stop Command

Function

Byte Count

Effects Address

Command Code

Message

Write

03

EX

F2

FF

Table 98. Kalypso Effects Addresses - All Stop Command

Effects Address

Assignment

00 PGM-PST

01

Mix/Effects 1

02

Mix/Effects 2

03

Mix/Effects 3

04

PGM-PST Secondary Partition

a

a

New effects address assignment associated with Kalypso.

05

Mix/Effects 1 Secondary Partition

a

06

Mix/Effects 2 Secondary Partition

a

07

Mix/Effects 3 Secondary Partition

a

0B